Development and Validation of an Optical Sensor-Based Automated Urine Flow Meter for Real-Time Patient Monitoring

Acute kidney injury (AKI) affects thousands of hospitalized patients annually, yet early detection remains challenging as serum creatinine elevation lags behind clinical deterioration. Decreased urine output (UO) represents a key diagnostic criterion of AKI, sometimes manifesting hours before biochemical changes; however, current manual monitoring methods are labor-intensive and prone to error. Here, we developed and validated a simple, cost-effective automated urine flow meter using non-contact optical sensors, a peristaltic pump, and microcontroller-based automation for precise, real-time monitoring of urine output in clinical settings, named P-meter. Three successive prototypes (V1, V2, V3) were validated against gold-standard gravimetric measurements over 285 h of testing during animal experiments that required bladder catheterization. Iterative refinement addressed miniaturization challenges, fluid dynamics optimization, and sensor positioning to achieve progressively improved accuracy. The optimized V3 prototype demonstrated further enhanced volumetric precision, stability, and flow accuracy with near-unity linearity vs. reference method (R<sup>2</sup> = 0.9889), minimal bias (mean error -0.1 mL), and 94.18% agreement within confidence limits (n = 86), outperforming the initial V1 prototype (R<sup>2</sup> = 0.9971, mean error -1.69 mL, n = 207) and intermediate V2 design (R<sup>2</sup> = 0.9941, mean error 3.63 mL, n = 390), primarily in terms of reduced bias and improved agreement. The P-meter offers accurate urine output monitoring at a lower cost than commercial systems, facilitating its use in early AKI detection and thereby improving patient outcomes.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-01-28
DOI
https://doi.org/10.3390/s26030849
Primary Topic
Intravenous Infusion Technology and Safety
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Validation of an Optical Sensor-Based Automated Urine Flow Meter for Real-Time Patient Monitoring

Michael Serhan, Bo Fu, Erica Forzani, Piyush Hota et al.
Sensors
Intravenous Infusion Technology and Safety
article

Development and Validation of an Optical Sensor-Based Automated Urine Flow Meter for Real-Time Patient Monitoring

Michael Serhan, Bo Fu, Erica Forzani, Piyush Hota, Adithya Shyamala Pandian, Pinar Cay-Durgun, Manni Mo, Naomi M. Gades, Peter Serhan, Peter Wiktor, Kevin Abi Karam, Leslie F. Thomas, Mary Laura Lind, Rodrigo E. Domínguez, Sandra Miranda
article en

Abstract

Acute kidney injury (AKI) affects thousands of hospitalized patients annually, yet early detection remains challenging as serum creatinine elevation lags behind clinical deterioration. Decreased urine output (UO) represents a key diagnostic criterion of AKI, sometimes manifesting hours before biochemical changes; however, current manual monitoring methods are labor-intensive and prone to error. Here, we developed and validated a simple, cost-effective automated urine flow meter using non-contact optical sensors, a peristaltic pump, and microcontroller-based automation for precise, real-time monitoring of urine output in clinical settings, named P-meter. Three successive prototypes (V1, V2, V3) were validated against gold-standard gravimetric measurements over 285 h of testing during animal experiments that required bladder catheterization. Iterative refinement addressed miniaturization challenges, fluid dynamics optimization, and sensor positioning to achieve progressively improved accuracy. The optimized V3 prototype demonstrated further enhanced volumetric precision, stability, and flow accuracy with near-unity linearity vs. reference method (R<sup>2</sup> = 0.9889), minimal bias (mean error -0.1 mL), and 94.18% agreement within confidence limits (n = 86), outperforming the initial V1 prototype (R<sup>2</sup> = 0.9971, mean error -1.69 mL, n = 207) and intermediate V2 design (R<sup>2</sup> = 0.9941, mean error 3.63 mL, n = 390), primarily in terms of reduced bias and improved agreement. The P-meter offers accurate urine output monitoring at a lower cost than commercial systems, facilitating its use in early AKI detection and thereby improving patient outcomes.

SensorsVol. 26(3)
Phoenix Children's Hospital (US), Mayo Clinic in Arizona (US), Mayo Clinic Hospital (US), BioElectronics (United States) (US), Arizona State University (US)
National Science Foundation, Arizona State University, National Institutes of Health
Decent work and economic growth
Openalex Percentile: Top 75%
Intravenous Infusion Technology and Safety
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.