Verifying the Reliability of a Hardware-Implemented TIS System in Phantom and Ex-vivo Experiments

Temporal Interference Stimulation (TIS) advancement is hindered by technical limitations. This study aims to overcome these by developing a precision system and experimentally validating its core principle, focal point steering via current ratio control, through cross-validation in phantom, ex vivo, and computational models. We performed invasive experiments applying 108 and 100 Hz for an 8 Hz difference at 1:1, 2:1, and 1:2 ratios, maintaining 2.1 mA total current, in phantoms, ex vivo mouse brain, and muscle. Results consistently matched TIS theory: the 8 Hz envelope peak was centered at 1:1 and predictably shifted toward the weaker current side at 2:1/1:2 ratios. High concordance between experiments and simulations confirmed steering was maintained despite different tissue impedances. This integrative validation confirms TIS steering feasibility and provides a validated platform for future personalized stimulation.

Authors

Publication Details

Journal
Journal of Magnetics
Published
2025-12-31
DOI
https://doi.org/10.4283/jmag.2025.30.4.825
Primary Topic
Neuroscience and Neural Engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Verifying the Reliability of a Hardware-Implemented TIS System in Phantom and Ex-vivo Experiments

Doyoung Pyeon, Youngjin Jung, Nayun Seo, Seungmin Hwang et al.
Journal of Magnetics
Neuroscience and Neural Engineering
article

Verifying the Reliability of a Hardware-Implemented TIS System in Phantom and Ex-vivo Experiments

Doyoung Pyeon, Youngjin Jung, Nayun Seo, Seungmin Hwang, Yeonghun Song, Jangwoo Park
article en

Abstract

Temporal Interference Stimulation (TIS) advancement is hindered by technical limitations. This study aims to overcome these by developing a precision system and experimentally validating its core principle, focal point steering via current ratio control, through cross-validation in phantom, ex vivo, and computational models. We performed invasive experiments applying 108 and 100 Hz for an 8 Hz difference at 1:1, 2:1, and 1:2 ratios, maintaining 2.1 mA total current, in phantoms, ex vivo mouse brain, and muscle. Results consistently matched TIS theory: the 8 Hz envelope peak was centered at 1:1 and predictably shifted toward the weaker current side at 2:1/1:2 ratios. High concordance between experiments and simulations confirmed steering was maintained despite different tissue impedances. This integrative validation confirms TIS steering feasibility and provides a validated platform for future personalized stimulation.

Journal of MagneticsVol. 30(4)
Openalex Percentile: Top 34%
Neuroscience and Neural Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Verifying the Reliability of a Hardware-Implemented TIS System in Phantom and Ex-vivo Experiments — Doyoung Pyeon, Youngjin Jung, et al. · Journal of Magnetics (2025) | TGRS Research Map | TGRS