Development of an Electromagnetic Radiation Screening System using Push-Shield Door for Radiation Safety

This study evaluates radiation exposure risks associated with baggage jamming in X-ray security inspection systems and proposes a new push-type shielding door mechanism to mitigate such exposure. Using the Monte Carlo code MCNPX v2.7 and the HDRK-Man computational phantom, simulations were conducted to estimate leakage and operator dose rates under various obstruction scenarios. The results demonstrated that when the lead curtain was fully open due to baggage jam, operator exposure reached up to 22.69 μSv/hr, exceeding public dose limits. Implementation of the newly designed shielding door reduced this dose to 0.06 μSv/hr, achieving a 99.7% reduction in exposure. The proposed system not only ensures compliance with domestic radiation safety regulations but also improves operational efficiency and inspection stability.

Authors

Publication Details

Journal
Journal of Magnetics
Published
2025-12-31
DOI
https://doi.org/10.4283/jmag.2025.30.4.776
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of an Electromagnetic Radiation Screening System using Push-Shield Door for Radiation Safety

Seung-Youl Lee
Journal of Magnetics
Radiation Dose and Imaging
article

Development of an Electromagnetic Radiation Screening System using Push-Shield Door for Radiation Safety

Seung-Youl Lee
article en

Abstract

This study evaluates radiation exposure risks associated with baggage jamming in X-ray security inspection systems and proposes a new push-type shielding door mechanism to mitigate such exposure. Using the Monte Carlo code MCNPX v2.7 and the HDRK-Man computational phantom, simulations were conducted to estimate leakage and operator dose rates under various obstruction scenarios. The results demonstrated that when the lead curtain was fully open due to baggage jam, operator exposure reached up to 22.69 μSv/hr, exceeding public dose limits. Implementation of the newly designed shielding door reduced this dose to 0.06 μSv/hr, achieving a 99.7% reduction in exposure. The proposed system not only ensures compliance with domestic radiation safety regulations but also improves operational efficiency and inspection stability.

Journal of MagneticsVol. 30(4)
Affordable and clean energy
Openalex Percentile: Top 28%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.