Markerless 3D biomechanical analysis of manual rice transplanting using YOLO11 and depth anything V2

Manual rice transplanting operation imposes severe biomechanical demands on agricultural workers, but quantitative assessment has been limited by practical limitations of marker-based motion capture in agricultural fields. This study presents a validated markerless framework integrating YOLOv11 pose estimation with Depth Anything V2 monocular depth prediction that is validated and field-deployable for three-dimensional biomechanical analysis. This framework extracts 17 anatomical keypoints and depth maps from standard video recordings (1080p, 30 fps). Full-body kinematics with 36 degrees of freedom are reconstructed following International Society of Biomechanics conventions. Numerical differentiation was performed for determining angular velocities, accelerations, and jerk along with Butterworth filtering (6 Hz cutoff) to reduce noise amplification inherent in high-order derivatives. Manual transplanting analysis (1366 frames, 48 transplanting cycles, 45.8 s, 64 hills/minute) yielded 25,276 validated kinematic measurements revealing three critical hazards: (1) Sustained trunk flexion (89.8 ± 3.3°) exceeded the 60° ergonomic threshold by 49 %, corresponding to 3.5–4.5 times bodyweight spinal compression; (2) Shoulder accelerations surpassed 600°/s² safety limits in 83.7 % of frames (peak: 11,603°/s²), indicating elevated rotator cuff injury risk; (3) High jerk values in 48.3 % of movements (mean: 1545°/s³) signaled poor motor control and tissue strain. The kinematic dataset provides robotic design specifications: peak joint velocities (350–400°/s), accelerations (450–700°/s²), and end-effector speeds (∼2.8 m/s). This validated markerless approach enables scalable field-based biomechanical assessment, reducing infrastructure costs by >99 % ($200K-500 K to $1K-1.5 K) while maintaining measurement rigor for occupational health evaluation and robotic system development.

Authors

Publication Details

Journal
Results in Engineering
Published
2026-01-28
DOI
https://doi.org/10.1016/j.rineng.2026.109329
Primary Topic
Agriculture and Farm Safety
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Markerless 3D biomechanical analysis of manual rice transplanting using YOLO11 and depth anything V2

Md. Ashraful Haque, Tapan Kumar Khura, Roaf Ahmad Parray, Dinesh Kumar et al.
Results in Engineering
Agriculture and Farm Safety
article

Markerless 3D biomechanical analysis of manual rice transplanting using YOLO11 and depth anything V2

Md. Ashraful Haque, Tapan Kumar Khura, Roaf Ahmad Parray, Dinesh Kumar, Pramod Kumar Sahoo, Shubham Chaudhary, Naveen Rachamalla, V Shobhan Naik, Adarsh Kumar
article en

Abstract

Manual rice transplanting operation imposes severe biomechanical demands on agricultural workers, but quantitative assessment has been limited by practical limitations of marker-based motion capture in agricultural fields. This study presents a validated markerless framework integrating YOLOv11 pose estimation with Depth Anything V2 monocular depth prediction that is validated and field-deployable for three-dimensional biomechanical analysis. This framework extracts 17 anatomical keypoints and depth maps from standard video recordings (1080p, 30 fps). Full-body kinematics with 36 degrees of freedom are reconstructed following International Society of Biomechanics conventions. Numerical differentiation was performed for determining angular velocities, accelerations, and jerk along with Butterworth filtering (6 Hz cutoff) to reduce noise amplification inherent in high-order derivatives. Manual transplanting analysis (1366 frames, 48 transplanting cycles, 45.8 s, 64 hills/minute) yielded 25,276 validated kinematic measurements revealing three critical hazards: (1) Sustained trunk flexion (89.8 ± 3.3°) exceeded the 60° ergonomic threshold by 49 %, corresponding to 3.5–4.5 times bodyweight spinal compression; (2) Shoulder accelerations surpassed 600°/s² safety limits in 83.7 % of frames (peak: 11,603°/s²), indicating elevated rotator cuff injury risk; (3) High jerk values in 48.3 % of movements (mean: 1545°/s³) signaled poor motor control and tissue strain. The kinematic dataset provides robotic design specifications: peak joint velocities (350–400°/s), accelerations (450–700°/s²), and end-effector speeds (∼2.8 m/s). This validated markerless approach enables scalable field-based biomechanical assessment, reducing infrastructure costs by >99 % ($200K-500 K to $1K-1.5 K) while maintaining measurement rigor for occupational health evaluation and robotic system development.

Results in EngineeringVol. 29
Industry, innovation and infrastructure
Openalex Percentile: Top 74%
Agriculture and Farm Safety
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Markerless 3D biomechanical analysis of manual rice transplanting using YOLO11 and depth anything V2 — Md. Ashraful Haque, Tapan Kumar Khura, et al. · Results in Engineering (2026) | TGRS Research Map | TGRS