Use of Calibrated Screw Technique (CAST) for complex vertebral compression fractures: retrospective evaluation of clinical outcomes and indications.

Background Vertebral compression fractures (VCFs), characterized by middle column involvement, osteonecrotic clefts, split morphology, or pedicle fractures, pose biomechanical challenges that reduce the effectiveness of conventional vertebroplasty and kyphoplasty. We evaluated the feasibility, safety, and clinical outcomes of the Calibrated Screw Technique (CAST), a minimally invasive approach combining percutaneous pedicle screw fixation and targeted cement augmentation, in patients with complex VCFs.Methods We retrospectively analyzed 147 consecutive patients (155 vertebral levels; mean age 80.1 years), primarily with osteoporotic fractures (80.6%), treated using CAST. Demographic, clinical, and radiographic data were collected at baseline, and at 1 and 6 months. Pain intensity was measured by the numeric rating scale (NRS), and patient perceived outcomes were assessed using patient global impression of change (PGIC). Radiographic outcomes included refracture rates at treated vertebrae, incidence of new fractures, and kyphotic angle correction in mobile fractures.Results CAST was technically feasible in all cases without major complications. Mean NRS scores improved significantly from 7.7 before the procedure to 3.6 at 1 month and 2.7 at 6 months (P < 0.0001). At the 1 month follow-up, 55.3% of patients reported feeling 'extremely' or 'much improved' on PGIC, increasing to 69.8% at 6 months. Radiographically, only one asymptomatic refracture occurred at 1 month (0.8%) and none at 6 months. New fracture incidence decreased from 13.8% at 1 month to 4.2% at 6 months.Conclusions In this study, CAST provided a safe, technically feasible, and durable solution for stabilization and pain relief in complex VCFs unsuitable for conventional augmentation, highlighting its value for challenging VCFs.

Authors

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2026-01-06
DOI
https://doi.org/10.48620/94092
Primary Topic
Spinal Fractures and Fixation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Use of Calibrated Screw Technique (CAST) for complex vertebral compression fractures: retrospective evaluation of clinical outcomes and indications.

Alessandro Cianfoni, Andrea A. Domenighetti, Maurizio Isalberti, Christian Commodaro et al.
Open Access CRIS of the University of Bern
Spinal Fractures and Fixation Techniques
article

Use of Calibrated Screw Technique (CAST) for complex vertebral compression fractures: retrospective evaluation of clinical outcomes and indications.

Alessandro Cianfoni, Andrea A. Domenighetti, Maurizio Isalberti, Christian Commodaro, Francesco Adduci, Marco Pileggi, Tomaso Villa, Luigi La Barbera, Joshua A Hirsch, Andrea Cardia
article en

Abstract

Background Vertebral compression fractures (VCFs), characterized by middle column involvement, osteonecrotic clefts, split morphology, or pedicle fractures, pose biomechanical challenges that reduce the effectiveness of conventional vertebroplasty and kyphoplasty. We evaluated the feasibility, safety, and clinical outcomes of the Calibrated Screw Technique (CAST), a minimally invasive approach combining percutaneous pedicle screw fixation and targeted cement augmentation, in patients with complex VCFs.Methods We retrospectively analyzed 147 consecutive patients (155 vertebral levels; mean age 80.1 years), primarily with osteoporotic fractures (80.6%), treated using CAST. Demographic, clinical, and radiographic data were collected at baseline, and at 1 and 6 months. Pain intensity was measured by the numeric rating scale (NRS), and patient perceived outcomes were assessed using patient global impression of change (PGIC). Radiographic outcomes included refracture rates at treated vertebrae, incidence of new fractures, and kyphotic angle correction in mobile fractures.Results CAST was technically feasible in all cases without major complications. Mean NRS scores improved significantly from 7.7 before the procedure to 3.6 at 1 month and 2.7 at 6 months (P < 0.0001). At the 1 month follow-up, 55.3% of patients reported feeling 'extremely' or 'much improved' on PGIC, increasing to 69.8% at 6 months. Radiographically, only one asymptomatic refracture occurred at 1 month (0.8%) and none at 6 months. New fracture incidence decreased from 13.8% at 1 month to 4.2% at 6 months.Conclusions In this study, CAST provided a safe, technically feasible, and durable solution for stabilization and pain relief in complex VCFs unsuitable for conventional augmentation, highlighting its value for challenging VCFs.

Open Access CRIS of the University of Bern
Openalex Percentile: Top 74%
Spinal Fractures and Fixation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.