Magnetic Field–Based Dose Modulation in Diagnostic Radiology: A Feasibility Study

This study evaluated whether a static magnetic field can modulate the electron-associated component of dose during diagnostic electromagnetic photon beam exposures. Doses were measured with a solid-state dosimeter at 60–110 kVp (10-kVp steps) on an X-ray radiation gene rator operated at 200 mA, 100 cm source-to-detector distance, 1.0 s, and 20 × 20 cm field. For each kVp, 20 repeated measurements were acquired under two conditions: no field versus a transverse ~0.5 T field generated by Nd magnets; output reproducibility was verified (all CV ≤ 0.05). With the field applied, doses were consistently but slightly lower at 60–90 kVp (all two- sided P > 0.05). Statistically significant reductions appeared at higher kVp: 100 kVp, 21.325 ± 0.155 vs 21.245 ± 0.076 mGy (P = 0.048); 110 kVp, 24.970 ± 0.108 vs 24.910 ± 0.072 mGy (P = 0.047). These findings support the feasibility of magnetic-field–induced dose modulation under diagnostic-energy conditions.

Authors

Publication Details

Journal
Journal of Magnetics
Published
2025-12-31
DOI
https://doi.org/10.4283/jmag.2025.30.4.837
Primary Topic
Radiation Effects and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Magnetic Field–Based Dose Modulation in Diagnostic Radiology: A Feasibility Study

Bo-Seok Chang, Jeong-min Seo
Journal of Magnetics
Radiation Effects and Dosimetry
article

Magnetic Field–Based Dose Modulation in Diagnostic Radiology: A Feasibility Study

Bo-Seok Chang, Jeong-min Seo
article en

Abstract

This study evaluated whether a static magnetic field can modulate the electron-associated component of dose during diagnostic electromagnetic photon beam exposures. Doses were measured with a solid-state dosimeter at 60–110 kVp (10-kVp steps) on an X-ray radiation gene rator operated at 200 mA, 100 cm source-to-detector distance, 1.0 s, and 20 × 20 cm field. For each kVp, 20 repeated measurements were acquired under two conditions: no field versus a transverse ~0.5 T field generated by Nd magnets; output reproducibility was verified (all CV ≤ 0.05). With the field applied, doses were consistently but slightly lower at 60–90 kVp (all two- sided P > 0.05). Statistically significant reductions appeared at higher kVp: 100 kVp, 21.325 ± 0.155 vs 21.245 ± 0.076 mGy (P = 0.048); 110 kVp, 24.970 ± 0.108 vs 24.910 ± 0.072 mGy (P = 0.047). These findings support the feasibility of magnetic-field–induced dose modulation under diagnostic-energy conditions.

Journal of MagneticsVol. 30(4)
Affordable and clean energy
Openalex Percentile: Top 30%
Radiation Effects and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Magnetic Field–Based Dose Modulation in Diagnostic Radiology: A Feasibility Study — Bo-Seok Chang, Jeong-min Seo · Journal of Magnetics (2025) | TGRS Research Map | TGRS