Investigating the Impact of Iron and Aluminum Coagulants on the Performance of Capacitive Deionization Technology for Domestic Water Purification

A significant advantage of membrane capacitive deionization (MCDI) lies in its ability to achieve medium to high water recovery rates. A prototype of MCDI unit demonstrated a recovery around 68% while consistently achieving salt removal efficiencies of ≥ 90% from feed water with a total dissolved solids (TDS) concentration of 1490 mg/L. However, the presence of coagulant-derived multivalent ions, particularly Fe<sup>2+</sup>, Fe<sup>3+</sup>, and Al<sup>3+</sup>, poses a challenge to long-term salt rejection efficiency. When Fe<sup>3+</sup> or Al<sup>3+</sup> was present at concentrations near 10 mg/L in feed water with a TDS of ~400 mg/L, the residual iron or aluminum concentration in the treated water exceeded the permissible limits defined by drinking water standards. Despite high removal efficiencies (> 90%) for key cations including Na<sup>+</sup>, Ca<sup>2+</sup>, Mg<sup>2+</sup>, Al<sup>3+</sup>, Fe<sup>2+</sup>, and Fe<sup>3+</sup>, regeneration studies revealed a distinct desorption trend: Mg<sup>2+</sup> > Na<sup>+</sup> > Ca<sup>2+</sup> > Al<sup>3+</sup> > Fe<sup>2+</sup> ≈ Fe<sup>3+</sup>. This trend indicates that Fe<sup>3+</sup> and Fe<sup>2+</sup> are the most strongly retained and thus the most scale-forming ion in MCDI systems, followed by Al<sup>3+</sup>. Salt adsorption capacity of NaCl is 0.66-4.14 mg/g and modeled using the modified Donnan model effectively described the nonlinear adsorption behavior and also for all other systems with and without coagulant ions. Due to the presence of divalent ions, Donnan potential decreased compared to NaCl system without coagulant ions. The presence of coagulant ions further decreased the Donnan potential. Energy consumed 68.2-78.6 kT/ion and mostly increased to 60.6-101.3 kT/ion during partially choked condition. Post-operational surface analyses using x-ray photoelectron spectroscopy (XPS) and energy-dispersive spectroscopy (EDS) confirmed the accumulation of these metal ions on the carbon electrode surfaces. The observed deposition of oxide and hydroxide of coagulant ions significantly impacts long-term MCDI performance, underscoring the need for pretreatment strategies and electrode material optimization to enhance the sustainability and effectiveness of MCDI in domestic water purification applications.

Authors

Institutions

Publication Details

Journal
Water Environment Research
Published
2026-01-28
DOI
https://doi.org/10.1002/wer.70278
Primary Topic
Membrane-based Ion Separation Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigating the Impact of Iron and Aluminum Coagulants on the Performance of Capacitive Deionization Technology for Domestic Water Purification

Dhriti Ranjan Saha, Hema Sagar Giddi, Tarini Mazumder
Water Environment Research
Membrane-based Ion Separation Techniques
article

Investigating the Impact of Iron and Aluminum Coagulants on the Performance of Capacitive Deionization Technology for Domestic Water Purification

Dhriti Ranjan Saha, Hema Sagar Giddi, Tarini Mazumder
article en

Abstract

A significant advantage of membrane capacitive deionization (MCDI) lies in its ability to achieve medium to high water recovery rates. A prototype of MCDI unit demonstrated a recovery around 68% while consistently achieving salt removal efficiencies of ≥ 90% from feed water with a total dissolved solids (TDS) concentration of 1490 mg/L. However, the presence of coagulant-derived multivalent ions, particularly Fe<sup>2+</sup>, Fe<sup>3+</sup>, and Al<sup>3+</sup>, poses a challenge to long-term salt rejection efficiency. When Fe<sup>3+</sup> or Al<sup>3+</sup> was present at concentrations near 10 mg/L in feed water with a TDS of ~400 mg/L, the residual iron or aluminum concentration in the treated water exceeded the permissible limits defined by drinking water standards. Despite high removal efficiencies (> 90%) for key cations including Na<sup>+</sup>, Ca<sup>2+</sup>, Mg<sup>2+</sup>, Al<sup>3+</sup>, Fe<sup>2+</sup>, and Fe<sup>3+</sup>, regeneration studies revealed a distinct desorption trend: Mg<sup>2+</sup> > Na<sup>+</sup> > Ca<sup>2+</sup> > Al<sup>3+</sup> > Fe<sup>2+</sup> ≈ Fe<sup>3+</sup>. This trend indicates that Fe<sup>3+</sup> and Fe<sup>2+</sup> are the most strongly retained and thus the most scale-forming ion in MCDI systems, followed by Al<sup>3+</sup>. Salt adsorption capacity of NaCl is 0.66-4.14 mg/g and modeled using the modified Donnan model effectively described the nonlinear adsorption behavior and also for all other systems with and without coagulant ions. Due to the presence of divalent ions, Donnan potential decreased compared to NaCl system without coagulant ions. The presence of coagulant ions further decreased the Donnan potential. Energy consumed 68.2-78.6 kT/ion and mostly increased to 60.6-101.3 kT/ion during partially choked condition. Post-operational surface analyses using x-ray photoelectron spectroscopy (XPS) and energy-dispersive spectroscopy (EDS) confirmed the accumulation of these metal ions on the carbon electrode surfaces. The observed deposition of oxide and hydroxide of coagulant ions significantly impacts long-term MCDI performance, underscoring the need for pretreatment strategies and electrode material optimization to enhance the sustainability and effectiveness of MCDI in domestic water purification applications.

Water Environment ResearchVol. 98(2)
Eureka College (US)
Eurostars
Clean water and sanitation
Openalex Percentile: Top 75%
Membrane-based Ion Separation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.