The Effects of Ovine-Derived Reinforced Tissue Matrix Surrounding Silicone-Based Implants in a Rat Prepectoral Reconstruction Model

Silicone-based implants have been widely used in breast reconstruction but have also been associated with poorly understood complications, including pathologic foreign body responses such as capsular contracture. In this study, we leveraged 3D-printing technology to generate silicone-based implants in a novel, anatomically relevant, prepectoral rat model. We used this model to evaluate the response to an extracellular matrix-based product: ovine-derived reinforced tissue matrix (RTM). Two-piece negative molds were developed through computer-aided design and 3D-printed. The molds were filled with various polydimethylsiloxane mixtures and dip-coated to fabricate implants. Implant material characterization revealed that the implants retained the original 3D-printed mold shape and qualitatively demonstrated a shell with an inner solid gel-like structure. Fabricated implants had smooth surfaces, as well as tunable features including implant stiffness (storage modulus). From initial studies in our rat model, placement of bilateral prepectoral implants allowed assessment of both muscle- and skin-facing capsules and were well-tolerated for at least 12 weeks. Comparison of the foreign body response between RTM-covered and uncovered (control) implants in this model revealed that the capsule thickness did not differ between groups at the 12-week endpoint. However, RTM reduced contractile fibroblasts (alpha-smooth muscle actin) and macrophages (Iba1) compared to the control. Our findings suggested that RTM may improve capsule quality by attenuating cells involved in fibrosis, even when total capsule thickness remains unchanged. However, these changes to cells involved in fibrosis were only observed at this early endpoint and may not predict long-term clinical outcomes.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2026-01-28
DOI
https://doi.org/10.3390/bioengineering13020150
Primary Topic
Breast Implant and Reconstruction
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Effects of Ovine-Derived Reinforced Tissue Matrix Surrounding Silicone-Based Implants in a Rat Prepectoral Reconstruction Model

Cameron Martin, Evan B. Marsh, Nicholas Fadell, Matthew D. Wood et al.
Bioengineering
Breast Implant and Reconstruction
article

The Effects of Ovine-Derived Reinforced Tissue Matrix Surrounding Silicone-Based Implants in a Rat Prepectoral Reconstruction Model

Cameron Martin, Evan B. Marsh, Nicholas Fadell, Matthew D. Wood, Lauren Schellhardt, Xiaowei A Li, Xiaochao Xia, Justin M. Sacks, Sai L. Pinni
article en

Abstract

Silicone-based implants have been widely used in breast reconstruction but have also been associated with poorly understood complications, including pathologic foreign body responses such as capsular contracture. In this study, we leveraged 3D-printing technology to generate silicone-based implants in a novel, anatomically relevant, prepectoral rat model. We used this model to evaluate the response to an extracellular matrix-based product: ovine-derived reinforced tissue matrix (RTM). Two-piece negative molds were developed through computer-aided design and 3D-printed. The molds were filled with various polydimethylsiloxane mixtures and dip-coated to fabricate implants. Implant material characterization revealed that the implants retained the original 3D-printed mold shape and qualitatively demonstrated a shell with an inner solid gel-like structure. Fabricated implants had smooth surfaces, as well as tunable features including implant stiffness (storage modulus). From initial studies in our rat model, placement of bilateral prepectoral implants allowed assessment of both muscle- and skin-facing capsules and were well-tolerated for at least 12 weeks. Comparison of the foreign body response between RTM-covered and uncovered (control) implants in this model revealed that the capsule thickness did not differ between groups at the 12-week endpoint. However, RTM reduced contractile fibroblasts (alpha-smooth muscle actin) and macrophages (Iba1) compared to the control. Our findings suggested that RTM may improve capsule quality by attenuating cells involved in fibrosis, even when total capsule thickness remains unchanged. However, these changes to cells involved in fibrosis were only observed at this early endpoint and may not predict long-term clinical outcomes.

BioengineeringVol. 13(2)
Washington University in St. Louis (US)
Openalex Percentile: Top 74%
Breast Implant and Reconstruction
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.