Comparison of four different multi-detector computed tomography based split renal function (SRF) evaluation methods and their correlation with nuclear scintigraphy derived SRF for functional assessment of potential living renal donors
Background and Objectives: Preoperative anatomical and functional evaluation of donor kidneys is crucial for successful renal transplantation. While multi-detector computed tomography (MDCT) angiography is the standard imaging modality for anatomical assessment, nuclear scintigraphy using Technetium-99m Diethylenetriamine Pentaacetate (Tc-99m DTPA) remains the gold standard for evaluating split renal function (SRF). However, MDCT-based SRF estimation has recently emerged as a viable alternative. The aim of this study is to compare four different MDCT-based SRF measurement techniques and assess their correlation with SRF obtained from nuclear scintigraphy. Materials and Methods: This prospective study included 111 living kidney donors from 2019 to 2021 who underwent MDCT angiography. SRF was estimated using four CT-based methods: total renal volume, cortical renal volume, ellipsoid method (all using semi-automated ROI-Region of Interest), and differential attenuation of contrast. All measurements were performed using an Advantage Workstation (GE). The calculated SRFs were compared with Tc-99m DTPA-based SRF using the Pearson correlation coefficient. Results: The mean age of donors was 44.32±10.25 years (range: 22–69). All four MDCT-based methods showed statistically significant correlation with nuclear scintigraphy SRF. For the right kidney, correlation coefficients (r) were 0.574 (total renal volume), 0.509 (cortical volume), 0.288 (ellipsoid method), and 0.323 (contrast attenuation); for the left kidney, r-values were 0.513, 0.473, 0.262, and 0.251, respectively (all p<0.001). Conclusion: MDCT-based SRF measurements demonstrate a significant correlation with nuclear scintigraphy. Given that MDCT angiography is routinely performed for anatomical evaluation, it can serve as a comprehensive, single-modality approach for both anatomical and functional assessment in living kidney donors. January 2026; Vol. 20(1):002. DOI: https://doi.org/10.55010/imcjms.20.002 *Correspondence: S Danish Iqbaal, Department of Community Medicine, Indira Gandhi Institute of Medical Sciences, Patna-800014, Bihar, India. Email: [email protected] © 2026 The Author(s). This is an open access article distributed under the terms of the Creative Commons Attribution License(CC BY 4.0).
Authors
- Rajnikant Prasad (ORCID: https://orcid.org/0000-0003-0409-2689)
- Aneesh Srivastava
- Hira Lal
- Sukanta Barai
- S Danish Iqbaal
Institutions
- Amrita Institute of Medical Sciences and Research Centre (IN)
- Sanjay Gandhi Post Graduate Institute of Medical Sciences (IN)
- Indira Gandhi Institute of Medical Sciences (IN)
- Medanta The Medicity (IN)
- Asian Institute of Medical Sciences (IN)
- Post Graduate Institute of Medical Education and Research (IN)
Publication Details
- Journal
- IMC Journal of Medical Science
- Published
- 2026-01-25
- DOI
- https://doi.org/10.55010/imcjms.20.002
- Primary Topic
- Renal and Vascular Pathologies
- Type
- article
- Field-Weighted Citation Impact
- 0.00