Soft lining materials in denture relining: Biological, mechanical, and clinical perspectives

Introduction. Loose-fitting dentures are a common clinical problem that compromises patient comfort, function, and prosthesis stability, primarily due to residual ridge resorption, systemic conditions, and excessive occlusal loading. Residual ridge resorption is a chronic and progressive process that reduces the quantity and quality of supporting tissues, particularly affecting removable dentures. Relining and rebasing procedures are widely used to restore denture adaptation, retention, and stability without fabricating a new prosthesis. Application of soft lining materials has gained clinical importance, especially in elderly patients with thin, sensitive, or traumatized oral mucosa. Material and method. Soft liners are classified into short-term materials, commonly referred to as tissue conditioners, and long-term soft liners. Tissue conditioners are viscoelastic materials used temporarily to promote mucosal healing, improve denture fit, and serve as functional impression materials. Long-term soft liners, including plasticized methacrylates and silicone-based materials, are indicated for patients with chronic mucosal discomfort, severe ridge resorption, or anatomical limitations. Result and discussion. Silicone-based soft liners demonstrate superior long-term elasticity, dimensional stability, and biocompatibility compared with acrylic-based liners. Clinical outcomes of denture relining depend on appropriate material selection, handling protocols, and bonding quality between the liner and denture base. Silicone soft liners, particularly autopolymerizing types, are favoured due to their sustained resilience and minimal tissue irritation. Overall, soft liners play a significant role in reducing mucosal trauma, improving stress distribution, and enhancing denture retention. Proper clinical indication and material selection are essential to achieve optimal long-term therapeutic outcomes in removable prosthodontics.

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-12-31
DOI
https://doi.org/10.5281/zenodo.18401140
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Soft lining materials in denture relining: Biological, mechanical, and clinical perspectives

Karina Mundiratri, Hendri Budi Gunawan, Fionna Adhelia Putri
Zenodo (CERN European Organization for Nuclear Research)
Dental materials and restorations
article

Soft lining materials in denture relining: Biological, mechanical, and clinical perspectives

Karina Mundiratri, Hendri Budi Gunawan, Fionna Adhelia Putri
article en

Abstract

Introduction. Loose-fitting dentures are a common clinical problem that compromises patient comfort, function, and prosthesis stability, primarily due to residual ridge resorption, systemic conditions, and excessive occlusal loading. Residual ridge resorption is a chronic and progressive process that reduces the quantity and quality of supporting tissues, particularly affecting removable dentures. Relining and rebasing procedures are widely used to restore denture adaptation, retention, and stability without fabricating a new prosthesis. Application of soft lining materials has gained clinical importance, especially in elderly patients with thin, sensitive, or traumatized oral mucosa. Material and method. Soft liners are classified into short-term materials, commonly referred to as tissue conditioners, and long-term soft liners. Tissue conditioners are viscoelastic materials used temporarily to promote mucosal healing, improve denture fit, and serve as functional impression materials. Long-term soft liners, including plasticized methacrylates and silicone-based materials, are indicated for patients with chronic mucosal discomfort, severe ridge resorption, or anatomical limitations. Result and discussion. Silicone-based soft liners demonstrate superior long-term elasticity, dimensional stability, and biocompatibility compared with acrylic-based liners. Clinical outcomes of denture relining depend on appropriate material selection, handling protocols, and bonding quality between the liner and denture base. Silicone soft liners, particularly autopolymerizing types, are favoured due to their sustained resilience and minimal tissue irritation. Overall, soft liners play a significant role in reducing mucosal trauma, improving stress distribution, and enhancing denture retention. Proper clinical indication and material selection are essential to achieve optimal long-term therapeutic outcomes in removable prosthodontics.

Zenodo (CERN European Organization for Nuclear Research)
Universitas Airlangga (ID)
Openalex Percentile: Top 28%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.