Evaluation of Composite Lead-Free Shield for Clinical Use in C-Arm Fluoroscopy

C-arm fluoroscopy provides essential real-time imaging for various interventional procedures but entails radiation exposure risks for both patients and medical staff. Conventional lead and lead-free shields offer high attenuation yet remain limited in clinical use due to weight, image artifacts, and procedural constraints. This study evaluated a lead-free composite shield composed of tungsten, tungsten carbide, bismuth, aluminum, and polyurethane, focusing on dose reduction, scatter shielding performance, image quality, and interactions with Automatic Brightness Control (ABC) in a C-arm environment. PHITS-based Monte Carlo simulations demonstrated strong attenuation in the low-to-mid energy range across 60–120 kVp. Experimental measurements showed attenuation rates of 59.6–70.8% (no filter), 45.4–55.4% (Al 2.5 mm), and 37.5–49.5% (Cu 0.25 mm), corresponding to 0.04 mmPb. Scattered radiation shielding efficiency ranged from 36–58% (1 layer) and 61– 80% (1.5 layers). Phantom tests confirmed an average 29% dose reduction without significant ABC-driven parameter increases, and SNR/CNR changes were not statistically significant (p > 0.05).

Authors

Publication Details

Journal
Journal of Magnetics
Published
2025-12-31
DOI
https://doi.org/10.4283/jmag.2025.30.4.651
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Composite Lead-Free Shield for Clinical Use in C-Arm Fluoroscopy

K. B. Kim, Sang Hyoun Choi, Jung-Ju Jo, Yoon Ho Shin
Journal of Magnetics
Radiation Dose and Imaging
article

Evaluation of Composite Lead-Free Shield for Clinical Use in C-Arm Fluoroscopy

K. B. Kim, Sang Hyoun Choi, Jung-Ju Jo, Yoon Ho Shin
article en

Abstract

C-arm fluoroscopy provides essential real-time imaging for various interventional procedures but entails radiation exposure risks for both patients and medical staff. Conventional lead and lead-free shields offer high attenuation yet remain limited in clinical use due to weight, image artifacts, and procedural constraints. This study evaluated a lead-free composite shield composed of tungsten, tungsten carbide, bismuth, aluminum, and polyurethane, focusing on dose reduction, scatter shielding performance, image quality, and interactions with Automatic Brightness Control (ABC) in a C-arm environment. PHITS-based Monte Carlo simulations demonstrated strong attenuation in the low-to-mid energy range across 60–120 kVp. Experimental measurements showed attenuation rates of 59.6–70.8% (no filter), 45.4–55.4% (Al 2.5 mm), and 37.5–49.5% (Cu 0.25 mm), corresponding to 0.04 mmPb. Scattered radiation shielding efficiency ranged from 36–58% (1 layer) and 61– 80% (1.5 layers). Phantom tests confirmed an average 29% dose reduction without significant ABC-driven parameter increases, and SNR/CNR changes were not statistically significant (p > 0.05).

Journal of MagneticsVol. 30(4)
Affordable and clean energy
Openalex Percentile: Top 28%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.