Sutureless-dehydrated amniotic membrane (Omnigen®) mounted on contact lens (OmniLenz®) in the treatment of small corneal perforations secondary to exposure keratitis in ICU patients
Omnigen®/OmniLenz® device provides a safe, effective, and non-invasive bedside treatment for small corneal perforations secondary to exposure keratitis in critically ill ICU patients. Its use enabled consistent tectonic restoration, rapid perforation closure, and resolution of infection-associated corneal pathology without procedure-related complications. This approach offers a practical alternative to urgent surgical intervention in patients unsuitable for operative care and may serve as a valuable addition to corneal perforation management protocols. Further studies with larger cohorts are needed to evaluate its safety and efficacy in larger perforations and to determine long-term outcomes, including corneal scarring and visual acuity.