Transient sinoatrial node dysfunction after pulsed-field pulmonary vein ablation: an image case report

Pulmonary vein pulsed-field ablation (PFA) is widely regarded as a safe procedure for patients with atrial fibrillation (AF), with sinoatrial disturbances as a rare complication. A 62-year-old female patient with paroxysmal AF underwent ablation using an 8-polar circular PFA catheter. During pulmonary vein isolation (PVI) of the right superior pulmonary vein, an intermittent increase in sinus rate was noted. Recurrent sinoatrial block was observed shortly after the procedure but resolved completely within six hours. This report presents the first documented case of transient sinoatrial node dysfunction as a complication of pulmonary vein PFA. Although the underlying mechanism-whether singular or multifactorial-remains unconfirmed, this case highlights the need for caution when utilizing the 8-polar circular PFA catheter.

Authors

Institutions

Publication Details

Journal
Frontiers in Cardiovascular Medicine
Published
2026-01-29
DOI
https://doi.org/10.3389/fcvm.2026.1745619
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transient sinoatrial node dysfunction after pulsed-field pulmonary vein ablation: an image case report

Jing Xu, He Le, F. Lu, Yitong Yin et al.
Frontiers in Cardiovascular Medicine
Atrial Fibrillation Management and Outcomes
article

Transient sinoatrial node dysfunction after pulsed-field pulmonary vein ablation: an image case report

Jing Xu, He Le, F. Lu, Yitong Yin, Henan Zhang, Enyuan Zhang, Wei Ma, Dongyan Wu
article en

Abstract

Pulmonary vein pulsed-field ablation (PFA) is widely regarded as a safe procedure for patients with atrial fibrillation (AF), with sinoatrial disturbances as a rare complication. A 62-year-old female patient with paroxysmal AF underwent ablation using an 8-polar circular PFA catheter. During pulmonary vein isolation (PVI) of the right superior pulmonary vein, an intermittent increase in sinus rate was noted. Recurrent sinoatrial block was observed shortly after the procedure but resolved completely within six hours. This report presents the first documented case of transient sinoatrial node dysfunction as a complication of pulmonary vein PFA. Although the underlying mechanism-whether singular or multifactorial-remains unconfirmed, this case highlights the need for caution when utilizing the 8-polar circular PFA catheter.

Frontiers in Cardiovascular MedicineVol. 13
Heart Rhythm Society (US), Tianjin Chest Hospital (CN), Tianjin Medical University (CN)
Tianjin Municipal Health Commission
Gender equality
Openalex Percentile: Top 77%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.