Ti6Al4V‐Bioglass‐Copper Composites for Load‐Bearing Implants

Total hip arthroplasty (THA) and total knee arthroplasty (TKA) utilize cobalt-chromium-molybdenum alloys; however, the release of cobalt ions is a significant clinical concern. Ceramic-based alternative systems also have concerns regarding long-term mechanical stability. Ti6Al4V (Ti64) is a better alternative; however, it is unsuitable for articulating surfaces due to its low wear resistance. We have designed and manufactured a novel Ti64-based composite by adding 45S5 bioglass (BG) and copper (Cu). Adding BG on titanium improves wear resistance and biocompatibility, whereas Cu addition improves mechanical strength while providing inherent lifelong bacterial resistance. Ti64, Ti64-1 wt% BG (Ti64-1BG), Ti64-3 wt% BG (Ti64-3BG), and Ti64-3 wt.% BG-3 wt.% (Ti64-3BG-3Cu) compositions were processed using the laser-directed energy deposition (L-DED) additive manufacturing (AM) technique. Microstructural characterisation and phase analysis were done to evaluate the influence of BG and Cu addition on Ti64. While BG was preferentially located along the melt pool boundaries, Cu was uniformly distributed throughout the sample. Uniaxial compression tests were conducted, and the addition of BG and Cu increased the strength. Biotribological analysis using flat-on-disc fixtures under fully immersed conditions in DMEM revealed that wear resistance improved due to the addition of BG and Cu to Ti64. Tribological testing revealed the formation of a protective nanoscale tribofilm on BG-containing samples, as indicated by increased contact resistance and reduced wear rates at higher loads. In vitro biocompatibility studies were done with human osteoblast (OB) cells for 3 and 7 days. Cell attachment and MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assays were performed to understand the influence of BG and Cu on biocompatibility, with Ti64 serving as a control. An antibacterial test was performed for 24 and 72 h using Staphylococcus aureus to evaluate the influence of Cu addition on the sample's antibacterial properties. Overall, the results demonstrated a superior implant material with enhanced biocompatibility, inherent antibacterial properties, and improved wear resistance through the innovative formation of a protective nanoscale tribofilm.

Authors

Institutions

Publication Details

Journal
Advanced Healthcare Materials
Published
2026-01-26
DOI
https://doi.org/10.1002/adhm.202504606
Primary Topic
Titanium Alloys Microstructure and Properties
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ti6Al4V‐Bioglass‐Copper Composites for Load‐Bearing Implants

Susmita Bose, Bryson White, Amit Bandyopadhyay, Lochan Upadhayay
Advanced Healthcare Materials
Titanium Alloys Microstructure and Properties
article

Ti6Al4V‐Bioglass‐Copper Composites for Load‐Bearing Implants

Susmita Bose, Bryson White, Amit Bandyopadhyay, Lochan Upadhayay
article en

Abstract

Total hip arthroplasty (THA) and total knee arthroplasty (TKA) utilize cobalt-chromium-molybdenum alloys; however, the release of cobalt ions is a significant clinical concern. Ceramic-based alternative systems also have concerns regarding long-term mechanical stability. Ti6Al4V (Ti64) is a better alternative; however, it is unsuitable for articulating surfaces due to its low wear resistance. We have designed and manufactured a novel Ti64-based composite by adding 45S5 bioglass (BG) and copper (Cu). Adding BG on titanium improves wear resistance and biocompatibility, whereas Cu addition improves mechanical strength while providing inherent lifelong bacterial resistance. Ti64, Ti64-1 wt% BG (Ti64-1BG), Ti64-3 wt% BG (Ti64-3BG), and Ti64-3 wt.% BG-3 wt.% (Ti64-3BG-3Cu) compositions were processed using the laser-directed energy deposition (L-DED) additive manufacturing (AM) technique. Microstructural characterisation and phase analysis were done to evaluate the influence of BG and Cu addition on Ti64. While BG was preferentially located along the melt pool boundaries, Cu was uniformly distributed throughout the sample. Uniaxial compression tests were conducted, and the addition of BG and Cu increased the strength. Biotribological analysis using flat-on-disc fixtures under fully immersed conditions in DMEM revealed that wear resistance improved due to the addition of BG and Cu to Ti64. Tribological testing revealed the formation of a protective nanoscale tribofilm on BG-containing samples, as indicated by increased contact resistance and reduced wear rates at higher loads. In vitro biocompatibility studies were done with human osteoblast (OB) cells for 3 and 7 days. Cell attachment and MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assays were performed to understand the influence of BG and Cu on biocompatibility, with Ti64 serving as a control. An antibacterial test was performed for 24 and 72 h using Staphylococcus aureus to evaluate the influence of Cu addition on the sample's antibacterial properties. Overall, the results demonstrated a superior implant material with enhanced biocompatibility, inherent antibacterial properties, and improved wear resistance through the innovative formation of a protective nanoscale tribofilm.

Advanced Healthcare Materials
Washington State University (US)
National Science Foundation, Washington State University, Division of Civil, Mechanical and Manufacturing Innovation
Openalex Percentile: Top 76%
Titanium Alloys Microstructure and Properties
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.