Imaging and Clinical Outcomes with Sentinel Cerebral Embolic Protection During TAVR: A Meta-Analysis of Randomized Trials with Trial Sequential Analysis

<b>Background:</b> Stroke and subclinical cerebral ischemia remain important neurological complications of transcatheter aortic valve replacement (TAVR). The Sentinel cerebral embolic protection (CEP) device is designed to capture embolic debris during TAVR, but its impact on clinical and imaging outcomes remains incompletely characterized. <b>Methods:</b> PubMed, Embase, and Cochrane databases were systematically searched for randomized controlled trials (RCTs) comparing Sentinel CEP versus no protection when TAVR was performed. Outcomes of interest included all stroke, disabling stroke, infarct volume by diffusion-weighted MRI in protected and unprotected areas, all-cause mortality, acute kidney injury, and major vascular complications. Risk ratios (RRs) and median differences with 95% confidence intervals (CIs) were calculated using random-effects models and trial sequential analysis (TSA) assessed evidence robustness. <b>Results:</b> Four RCTs including 10,986 patients were analyzed. Sentinel CEP did not significantly reduce clinical stroke (RR 0.88, 95% CI 0.69-1.12) or disabling stroke (RR 0.68, 95% CI 0.41-1.14). Pooled DW-MRI data showed a significant reduction in new ischemic lesion volume within Sentinel CEP-protected territories (difference in medians -75.7 mm<sup>3</sup>; 95% CI -130.4 to -21.0). Subgroup analyses in elderly, female, and high-surgical-risk patients revealed no benefit with Sentinel CEP. Additionally, TSA indicated that current data are underpowered for definitive conclusions. <b>Conclusions:</b> The Sentinel CEP device during TAVR did not significantly reduce clinical stroke but was associated with lower MRI-detected ischemic lesion volumes compared with no protection. Further adequately powered RCTs integrating clinical and imaging endpoints are needed to define its role in neuroprotection during TAVR.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-01-22
DOI
https://doi.org/10.3390/jcm15020914
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Imaging and Clinical Outcomes with Sentinel Cerebral Embolic Protection During TAVR: A Meta-Analysis of Randomized Trials with Trial Sequential Analysis

Adham Ramadan, Shanmukh Sai Pavan Lingamsetty, Mohamed Doma, Jaswanth Jasti et al.
Journal of Clinical Medicine
Cardiac Valve Diseases and Treatments
article

Imaging and Clinical Outcomes with Sentinel Cerebral Embolic Protection During TAVR: A Meta-Analysis of Randomized Trials with Trial Sequential Analysis

Adham Ramadan, Shanmukh Sai Pavan Lingamsetty, Mohamed Doma, Jaswanth Jasti, Venkata Vedantam, Chenna Reddy Tera, Mangesh Kritya, Pedro A. Villablanca, Andrew M. Goldsweig, Sahas Reddy Jitta, Mohan Chandra Vinay Bharadwaj Gudiwada, Priyanka Vatsavayi
article en

Abstract

<b>Background:</b> Stroke and subclinical cerebral ischemia remain important neurological complications of transcatheter aortic valve replacement (TAVR). The Sentinel cerebral embolic protection (CEP) device is designed to capture embolic debris during TAVR, but its impact on clinical and imaging outcomes remains incompletely characterized. <b>Methods:</b> PubMed, Embase, and Cochrane databases were systematically searched for randomized controlled trials (RCTs) comparing Sentinel CEP versus no protection when TAVR was performed. Outcomes of interest included all stroke, disabling stroke, infarct volume by diffusion-weighted MRI in protected and unprotected areas, all-cause mortality, acute kidney injury, and major vascular complications. Risk ratios (RRs) and median differences with 95% confidence intervals (CIs) were calculated using random-effects models and trial sequential analysis (TSA) assessed evidence robustness. <b>Results:</b> Four RCTs including 10,986 patients were analyzed. Sentinel CEP did not significantly reduce clinical stroke (RR 0.88, 95% CI 0.69-1.12) or disabling stroke (RR 0.68, 95% CI 0.41-1.14). Pooled DW-MRI data showed a significant reduction in new ischemic lesion volume within Sentinel CEP-protected territories (difference in medians -75.7 mm<sup>3</sup>; 95% CI -130.4 to -21.0). Subgroup analyses in elderly, female, and high-surgical-risk patients revealed no benefit with Sentinel CEP. Additionally, TSA indicated that current data are underpowered for definitive conclusions. <b>Conclusions:</b> The Sentinel CEP device during TAVR did not significantly reduce clinical stroke but was associated with lower MRI-detected ischemic lesion volumes compared with no protection. Further adequately powered RCTs integrating clinical and imaging endpoints are needed to define its role in neuroprotection during TAVR.

Journal of Clinical MedicineVol. 15(2)
East Tennessee State University (US), Boston Medical Center (US), Houston Methodist (US), Beth Israel Deaconess Medical Center (US), Baystate Medical Center (US), Harvard University (US), Reading Hospital (US), Henry Ford Hospital (US), Massachusetts General Hospital (US), Sisters of Mercy Health System (US), Baystate Health (US), Mercy Health (US), University of Nebraska Medical Center (US)
Good health and well-being
Openalex Percentile: Top 78%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.