Data-Driven Motion Correction Algorithm: Validation in [13N]NH3 Dynamic PET/CT Scans

<b>Background</b>: Motion is a long-standing problem in cardiac PET/CT. An automated data-driven motion correction (DDMC) algorithm for within-reconstruction motion correction (MC) has been developed and validated in static images from [<sup>13</sup>N]NH<sub>3</sub> and <sup>82</sup>Rb PET/CT. This study aims to validate DDMC in dynamic [<sup>13</sup>N]NH<sub>3</sub> PET/CT, and to explore the added value of DDMC in the evaluation of myocardial motion. <b>Methods</b>: Thirty-six PET/CT studies from normal patients and forty-three scans from patients with myocardial ischemia were processed using QPET software without MC (NMC), using manual in-software MC (ISMC), and DDMC. Differences in the mean values of rest-, stress-MBF, and CFR; and differences in effect size related to the use and type of MC method were explored. Moreover, motion vectors provided by DDMC were analyzed to evaluate differences in myocardial motion between scan phases and axes, and to elucidate changes in MBF quantification in relation to the motion extent. <b>Results</b>: In both subgroups, repeated measures ANOVA showed that the use of MC significantly increased regional and global stress-MBF and CFR values (<i>p</i> < 0.05), regardless of the MC method. Paired <i>t</i>-test analysis demonstrated a comparable ES between MC tools, despite minor differences in Cx, RCA and global rest-MBF values. High-intensity motion (>6 mm) proved to be present almost exclusively in the <i>Z</i> (cranio-caudal) direction. In the same axis, motion was significantly higher during stress than rest, regardless of patients' subgroup. Finally, the Jonckheere trend test showed a significant trend caused by motion in s-MBF values, in which lower stress-MBF values were observed in response to motion extent increments. <b>Conclusions</b>: DDMC is feasible to perform in [<sup>13</sup>N]NH<sub>3</sub> dynamic acquisitions and provides similar MBF/CFR values than manual ISMC. The use of DDMC reduces post-processing times and observer variability, and allows a more extensive evaluation of motion. MC is highly recommended when using QPET, as motion in the <i>Z</i>-axis during stress scans negatively impacts stress-MBF quantification.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-01-26
DOI
https://doi.org/10.3390/jcm15030984
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Data-Driven Motion Correction Algorithm: Validation in [13N]NH3 Dynamic PET/CT Scans

Tonantzin Samara Martínez-Lucio, Riemer H. J. A. Slart, Charles Hayden, Oscar Isaac Mendoza-Ibañez et al.
Journal of Clinical Medicine
Medical Imaging Techniques and Applications
article

Data-Driven Motion Correction Algorithm: Validation in [13N]NH3 Dynamic PET/CT Scans

Tonantzin Samara Martínez-Lucio, Riemer H. J. A. Slart, Charles Hayden, Oscar Isaac Mendoza-Ibañez, Friso M. van der Zant, Remco J. J. Knol, Sergiy V. Lazarenko
article en

Abstract

<b>Background</b>: Motion is a long-standing problem in cardiac PET/CT. An automated data-driven motion correction (DDMC) algorithm for within-reconstruction motion correction (MC) has been developed and validated in static images from [<sup>13</sup>N]NH<sub>3</sub> and <sup>82</sup>Rb PET/CT. This study aims to validate DDMC in dynamic [<sup>13</sup>N]NH<sub>3</sub> PET/CT, and to explore the added value of DDMC in the evaluation of myocardial motion. <b>Methods</b>: Thirty-six PET/CT studies from normal patients and forty-three scans from patients with myocardial ischemia were processed using QPET software without MC (NMC), using manual in-software MC (ISMC), and DDMC. Differences in the mean values of rest-, stress-MBF, and CFR; and differences in effect size related to the use and type of MC method were explored. Moreover, motion vectors provided by DDMC were analyzed to evaluate differences in myocardial motion between scan phases and axes, and to elucidate changes in MBF quantification in relation to the motion extent. <b>Results</b>: In both subgroups, repeated measures ANOVA showed that the use of MC significantly increased regional and global stress-MBF and CFR values (<i>p</i> < 0.05), regardless of the MC method. Paired <i>t</i>-test analysis demonstrated a comparable ES between MC tools, despite minor differences in Cx, RCA and global rest-MBF values. High-intensity motion (>6 mm) proved to be present almost exclusively in the <i>Z</i> (cranio-caudal) direction. In the same axis, motion was significantly higher during stress than rest, regardless of patients' subgroup. Finally, the Jonckheere trend test showed a significant trend caused by motion in s-MBF values, in which lower stress-MBF values were observed in response to motion extent increments. <b>Conclusions</b>: DDMC is feasible to perform in [<sup>13</sup>N]NH<sub>3</sub> dynamic acquisitions and provides similar MBF/CFR values than manual ISMC. The use of DDMC reduces post-processing times and observer variability, and allows a more extensive evaluation of motion. MC is highly recommended when using QPET, as motion in the <i>Z</i>-axis during stress scans negatively impacts stress-MBF quantification.

Journal of Clinical MedicineVol. 15(3)
University Medical Center Groningen (NL), University of Groningen (NL), Northwest Hospital (US), Medical Solutions (GB), University of Twente (NL)
Openalex Percentile: Top 78%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.