Effects of neutron irradiation on LGADs with broad multiplication layer and varied carbon-enriched doses: A study on timing performance and gain deterioration

In this radiation tolerance study, Low Gain Avalanche Detectors (LGADs) with a carbon-enriched broad and shallow multiplication layer were examined in comparison to identical non-carbonated LGADs. Manufactured at IMB-CNM, the sensors underwent neutron irradiation at the TRIGRA reactor in Ljubljana, reaching a fluence of 2.5 × 10 15 n eq cm -2 . The results revealed a smaller deactivation of Boron and improved resistance to radiation in carbonated LGADs. The study demonstrated the potential benefits of carbon enrichment in mitigating radiation damage effects, particularly the acceptor removal mechanism, reducing the acceptor removal constant by more than a factor of two. Additionally, time resolution and collected charge degradation due to irradiation were observed, with carbonated samples exhibiting better radiation tolerance. A noise analysis focused on baseline noise and thermally generated pulses showed the presence of spurious thermal-generated pulses attributed to a excessive small distance between the gain layer end and the p-stop implant at the periphery of the pad for the characterized LGAD design; however, the operation performance of the devices was unaffected.

Authors

Institutions

Publication Details

Journal
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Published
2026-01-27
DOI
https://doi.org/10.1016/j.nima.2026.171305
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of neutron irradiation on LGADs with broad multiplication layer and varied carbon-enriched doses: A study on timing performance and gain deterioration

R. Jaramillo, A. Merlos, E. Navarrete Ramos, I. Vila et al.
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Particle Detector Development and Performance
article

Effects of neutron irradiation on LGADs with broad multiplication layer and varied carbon-enriched doses: A study on timing performance and gain deterioration

R. Jaramillo, A. Merlos, E. Navarrete Ramos, I. Vila, J. Duarte-Campderros, M. Fernández, C. Quintana, P. Martínez Ruiz del Árbol, J. González, J. Villegas, G. Gómez, S. Hidalgo, A. Gómez-Carrera
article en

Abstract

In this radiation tolerance study, Low Gain Avalanche Detectors (LGADs) with a carbon-enriched broad and shallow multiplication layer were examined in comparison to identical non-carbonated LGADs. Manufactured at IMB-CNM, the sensors underwent neutron irradiation at the TRIGRA reactor in Ljubljana, reaching a fluence of 2.5 × 10 15 n eq cm -2 . The results revealed a smaller deactivation of Boron and improved resistance to radiation in carbonated LGADs. The study demonstrated the potential benefits of carbon enrichment in mitigating radiation damage effects, particularly the acceptor removal mechanism, reducing the acceptor removal constant by more than a factor of two. Additionally, time resolution and collected charge degradation due to irradiation were observed, with carbonated samples exhibiting better radiation tolerance. A noise analysis focused on baseline noise and thermally generated pulses showed the presence of spurious thermal-generated pulses attributed to a excessive small distance between the gain layer end and the p-stop implant at the periphery of the pad for the characterized LGAD design; however, the operation performance of the devices was unaffected.

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated EquipmentVol. 1085
Centro Nacional de Aceleradores (ES), Instituto de Física de Cantabria (ES), Institut de Microelectrònica de Barcelona (ES)
CERN, Ministerio de Ciencia, Innovación y Universidades, European Commission, Ministerio de Ciencia e Innovación, European Regional Development Fund, Agencia Estatal de Investigación, FP7 Research infrastructures
Openalex Percentile: Top 73%
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.