Reliable quantification of liquid oxygenated products in CO2/CH4 plasma-catalytic conversion

• Oxygenate quantification methods strongly affect conclusions on catalytic performance. • Indirect subtraction method overestimates oxygenate selectivity by up to 10 × . • Cold bath recovers only 50% alcohols and 10% ketones, underestimating selectivity. • Direct oxygenate quantification with a heated transfer line is more reliable. • Oxygenate selectivity remains low (< 3 %) and barely depends on the catalyst. The direct conversion of CO 2 and CH 4 into oxygenated products via plasma catalysis offers a promising route for biogas valorization, generating molecules usable as fuels or fuel additives, or convertible into energy carriers. However, many studies lack rigor in the quantification of oxygenate selectivity, often leading to overestimations and misleading conclusions regarding catalyst performance and energy efficiency. Typically, gaseous products are analyzed online, while liquid products are collected and analyzed offline. Oxygenate selectivity is often estimated indirectly by subtracting selectivities of other carbon products from 100%, a method that lacks accuracy and tends to overestimate performance. This work highlights the need for accurate and reliable analytical approaches to provide a realistic assessment of plasma-assisted CO 2 and CH 4 conversion and guide future research. An improved experimental setup is proposed, keeping all products in the gas phase using a heated transfer line and enabling direct online quantification by gas chromatography directly after the reactor. This approach minimizes errors from incomplete condensation and indirect calculations, achieving a carbon balance close to 95%. Beyond analytical considerations, the conversion of CO 2 and CH 4 into oxygenated products by plasma catalysis remains a challenge. Results indicate that while catalysts enhance overall conversion, their effect on oxygenate selectivity is limited. These findings suggest that future work should focus on tailoring plasma conditions rather than solely on catalyst optimization. Overall, this study emphasizes the importance of robust analytical methods as a foundation for better understanding reaction mechanisms and for guiding future research on energy conversion by plasma catalysis.

Authors

Institutions

Publication Details

Journal
Energy Conversion and Management
Published
2026-01-27
DOI
https://doi.org/10.1016/j.enconman.2026.121115
Citations
1
Primary Topic
Plasma Applications and Diagnostics
Type
article
Field-Weighted Citation Impact
31.92
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reliable quantification of liquid oxygenated products in CO2/CH4 plasma-catalytic conversion

Xavier Duten, Noelia Merino, Stéphanie Ognier, Maria Mikhail et al.
1 citations
Energy Conversion and Management
Plasma Applications and Diagnostics
31.92
article

Reliable quantification of liquid oxygenated products in CO2/CH4 plasma-catalytic conversion

Xavier Duten, Noelia Merino, Stéphanie Ognier, Maria Mikhail, Michael Tatoulian
article en
1 citations

Abstract

• Oxygenate quantification methods strongly affect conclusions on catalytic performance. • Indirect subtraction method overestimates oxygenate selectivity by up to 10 × . • Cold bath recovers only 50% alcohols and 10% ketones, underestimating selectivity. • Direct oxygenate quantification with a heated transfer line is more reliable. • Oxygenate selectivity remains low (< 3 %) and barely depends on the catalyst. The direct conversion of CO 2 and CH 4 into oxygenated products via plasma catalysis offers a promising route for biogas valorization, generating molecules usable as fuels or fuel additives, or convertible into energy carriers. However, many studies lack rigor in the quantification of oxygenate selectivity, often leading to overestimations and misleading conclusions regarding catalyst performance and energy efficiency. Typically, gaseous products are analyzed online, while liquid products are collected and analyzed offline. Oxygenate selectivity is often estimated indirectly by subtracting selectivities of other carbon products from 100%, a method that lacks accuracy and tends to overestimate performance. This work highlights the need for accurate and reliable analytical approaches to provide a realistic assessment of plasma-assisted CO 2 and CH 4 conversion and guide future research. An improved experimental setup is proposed, keeping all products in the gas phase using a heated transfer line and enabling direct online quantification by gas chromatography directly after the reactor. This approach minimizes errors from incomplete condensation and indirect calculations, achieving a carbon balance close to 95%. Beyond analytical considerations, the conversion of CO 2 and CH 4 into oxygenated products by plasma catalysis remains a challenge. Results indicate that while catalysts enhance overall conversion, their effect on oxygenate selectivity is limited. These findings suggest that future work should focus on tailoring plasma conditions rather than solely on catalyst optimization. Overall, this study emphasizes the importance of robust analytical methods as a foundation for better understanding reaction mechanisms and for guiding future research on energy conversion by plasma catalysis.

Energy Conversion and ManagementVol. 352
Centre National de la Recherche Scientifique (FR), Chimie ParisTech - PSL (FR), Sorbonne Université (FR), Université Sorbonne Paris Nord (FR), Laboratoire des Sciences des Procédés et des Matériaux (FR), Institut de Recherche de Chimie Paris (FR), Universidad Luterana Salvadoreña (SV)
Affordable and clean energy
Openalex Percentile: Top 1%
Plasma Applications and Diagnostics
31.92
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.