Ultrasensitive Impedimetric Electrochemical DNA Biosensor for Detection of Enterotoxigenic <i>Escherichia coli</i> (ETEC)

Enterotoxigenic <i>Escherichia coli</i> (ETEC) is a pathogenic strain of <i>E. coli</i>, which is transmitted via food and water, primarily causing diarrhea in children below 5. Due to similar biochemical properties, conventional culture and biochemical identification methods are unsuitable for distinguishing ETEC. Immunoassay and molecular detection are alternative techniques for detecting ETEC, which target heat-labile (LT) and heat-stable (ST) enterotoxins. However, they may require specialized equipment, and some methods may require a pre-enrichment process, making them unsuitable for rapid and on-site detection. This study designs a DNA-based electrochemical biosensor, specifically for detecting the <i>heat-labile toxin</i> (<i>LT</i>) gene of ETEC. The screen-printed electrode (SPE) was functionalized with diazonium salt and immobilized with an aminated-LT probe, which was confirmed by Fourier transform infrared spectroscopy (FTIR), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). This biosensor showed high efficiency in determining ETEC's DNA in the range of 1.9 × 10<sup>-8</sup> μg/mL -1.9 μg/mL with a limit of detection (LOD) of 1.9 × 10<sup>-8</sup> μg/mL. The developed biosensor exhibited high specificity without cross-reaction with other foodborne pathogenic bacteria, including <i>Shigella dysenteriae</i>, <i>Salmonella</i> Typhi, and <i>E. coli</i> ATCC25922. Moreover, this biosensor was challenged with spiked samples, prepared by the standard addition method, which demonstrated good performance, represented by good accuracy (Recovery >90%) and precision (coefficient of variation or COV < 10%). This is a promising technology that has the potential to be further developed as a point-of-need for medical diagnosis and epidemiological surveillance.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2026-01-27
DOI
https://doi.org/10.1021/acsomega.5c08712
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultrasensitive Impedimetric Electrochemical DNA Biosensor for Detection of Enterotoxigenic Escherichia coli (ETEC)

Mongkol Techakasikornpanich, Abdelhamid Elaissari, Kulachart Jangpatarapongsa, Abdelhamid Errachid et al.
ACS Omega
Advanced biosensing and bioanalysis techniques
article

Ultrasensitive Impedimetric Electrochemical DNA Biosensor for Detection of Enterotoxigenic Escherichia coli (ETEC)

Mongkol Techakasikornpanich, Abdelhamid Elaissari, Kulachart Jangpatarapongsa, Abdelhamid Errachid, Patcharapan Suwannin, Nadia Zine, Marie Hangouet, Jirawan Jindakaew, Duangporn Polpanich
article en

Abstract

Enterotoxigenic <i>Escherichia coli</i> (ETEC) is a pathogenic strain of <i>E. coli</i>, which is transmitted via food and water, primarily causing diarrhea in children below 5. Due to similar biochemical properties, conventional culture and biochemical identification methods are unsuitable for distinguishing ETEC. Immunoassay and molecular detection are alternative techniques for detecting ETEC, which target heat-labile (LT) and heat-stable (ST) enterotoxins. However, they may require specialized equipment, and some methods may require a pre-enrichment process, making them unsuitable for rapid and on-site detection. This study designs a DNA-based electrochemical biosensor, specifically for detecting the <i>heat-labile toxin</i> (<i>LT</i>) gene of ETEC. The screen-printed electrode (SPE) was functionalized with diazonium salt and immobilized with an aminated-LT probe, which was confirmed by Fourier transform infrared spectroscopy (FTIR), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). This biosensor showed high efficiency in determining ETEC's DNA in the range of 1.9 × 10<sup>-8</sup> μg/mL -1.9 μg/mL with a limit of detection (LOD) of 1.9 × 10<sup>-8</sup> μg/mL. The developed biosensor exhibited high specificity without cross-reaction with other foodborne pathogenic bacteria, including <i>Shigella dysenteriae</i>, <i>Salmonella</i> Typhi, and <i>E. coli</i> ATCC25922. Moreover, this biosensor was challenged with spiked samples, prepared by the standard addition method, which demonstrated good performance, represented by good accuracy (Recovery >90%) and precision (coefficient of variation or COV < 10%). This is a promising technology that has the potential to be further developed as a point-of-need for medical diagnosis and epidemiological surveillance.

ACS OmegaVol. 11(5)
Université Claude Bernard Lyon 1 (FR), Thammasat University (TH), Centre National de la Recherche Scientifique (FR), National Science and Technology Development Agency (TH), Mahidol University (TH), National Nanotechnology Center (TH), Institut des Sciences Analytiques (FR)
Openalex Percentile: Top 77%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.