Reliability of Sternocleidomastoid Muscle Stiffness Assessment Using Shear-Wave Elastography Under a Standardized Protocol with Novice and Experienced Examiners: An Intra- and Inter-Examiner Reliability Study

<i>Background and Objectives</i>: Sternocleidomastoid (SCM) dysfunction is commonly implicated in several musculoskeletal conditions. Accordingly, shear-wave elastography has been used to characterize SCM stiffness in asymptomatic and clinical cohorts. However, the only reproducibility study available reported limited reliability, so clinical interpretations should be made with caution. Therefore, this study revisits key methodological aspects of that protocol to assess intra-examiner reliability and includes two examiners with different levels of expertise to evaluate inter-examiner reliability. <i>Materials and Methods</i>: A longitudinal observational study was conducted, recruiting twenty-five asymptomatic participants. Two examiners with different experience levels participated in this study after following structured training. For each side, images were obtained in immediate succession in the sequence experienced-novice-experienced-novice (with side order randomized), using an ROI spanning full muscle thickness, stabilizing approximately 10 s before freezing to record Young's modulus and shear-wave speed. <i>Results</i>: Inter-examiner agreement was good-excellent: single-measurement ICCs were 0.77-0.86, improving to 0.79-0.87 when averaging two trials, which also reduced the standard error of measurement (SEM) and minimal detectable changes (MDCs). Between-examiner mean differences were small and nonsignificant (<i>p</i> ≥ 0.068). Intra-examiner reliability was excellent (ICC ≈ 0.93-0.94) with small absolute errors. Precision was high (SEM ~5-6 kPa; 0.22 m/s), and MDCs were ~15-16 kPa and ~0.60 m/s, with no trial-to-trial bias (all <i>p</i> ≥ 0.311). <i>Conclusions</i>: The revised protocol showed excellent intra-examiner repeatability and good-excellent inter-examiner reliability with minimal bias. Averaging two acquisitions improved precision, while a single operator optimized longitudinal stability.

Authors

Institutions

Publication Details

Journal
Medicina
Published
2026-01-27
DOI
https://doi.org/10.3390/medicina62020267
Primary Topic
Scoliosis diagnosis and treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reliability of Sternocleidomastoid Muscle Stiffness Assessment Using Shear-Wave Elastography Under a Standardized Protocol with Novice and Experienced Examiners: An Intra- and Inter-Examiner Reliability Study

Germán Monclús-Díez, Davinia Vicente-Campos, Ricardo Ortega-Santiago, Mónica López-Redondo et al.
Medicina
Scoliosis diagnosis and treatment
article

Reliability of Sternocleidomastoid Muscle Stiffness Assessment Using Shear-Wave Elastography Under a Standardized Protocol with Novice and Experienced Examiners: An Intra- and Inter-Examiner Reliability Study

Germán Monclús-Díez, Davinia Vicente-Campos, Ricardo Ortega-Santiago, Mónica López-Redondo, Jorge Buffet-García, Juan Antonio Valera-Calero, Sandra Sánchez-Jorge, Umut Varol
article en

Abstract

<i>Background and Objectives</i>: Sternocleidomastoid (SCM) dysfunction is commonly implicated in several musculoskeletal conditions. Accordingly, shear-wave elastography has been used to characterize SCM stiffness in asymptomatic and clinical cohorts. However, the only reproducibility study available reported limited reliability, so clinical interpretations should be made with caution. Therefore, this study revisits key methodological aspects of that protocol to assess intra-examiner reliability and includes two examiners with different levels of expertise to evaluate inter-examiner reliability. <i>Materials and Methods</i>: A longitudinal observational study was conducted, recruiting twenty-five asymptomatic participants. Two examiners with different experience levels participated in this study after following structured training. For each side, images were obtained in immediate succession in the sequence experienced-novice-experienced-novice (with side order randomized), using an ROI spanning full muscle thickness, stabilizing approximately 10 s before freezing to record Young's modulus and shear-wave speed. <i>Results</i>: Inter-examiner agreement was good-excellent: single-measurement ICCs were 0.77-0.86, improving to 0.79-0.87 when averaging two trials, which also reduced the standard error of measurement (SEM) and minimal detectable changes (MDCs). Between-examiner mean differences were small and nonsignificant (<i>p</i> ≥ 0.068). Intra-examiner reliability was excellent (ICC ≈ 0.93-0.94) with small absolute errors. Precision was high (SEM ~5-6 kPa; 0.22 m/s), and MDCs were ~15-16 kPa and ~0.60 m/s, with no trial-to-trial bias (all <i>p</i> ≥ 0.311). <i>Conclusions</i>: The revised protocol showed excellent intra-examiner repeatability and good-excellent inter-examiner reliability with minimal bias. Averaging two acquisitions improved precision, while a single operator optimized longitudinal stability.

MedicinaVol. 62(2)
Universidad Complutense de Madrid (ES), Universidad Rey Juan Carlos (ES), Universidad Francisco de Vitoria (ES)
Openalex Percentile: Top 77%
Scoliosis diagnosis and treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.