Use of a composite, <scp>3D</scp> ‐printed patch as a partial airway replacement: A pilot study on the porcine model

Abstract Tracheal replacement is an unmet clinical need, as patients with long or complex airway defects are managed with tracheostomy or permanent stents. Experimental and clinical research is ongoing in order to find safe airway substitutes; however, the strategies under investigation suffer from major limitations, such as unsatisfactory re‐epithelialization, insufficient long‐term mechanical support, and complex ex vivo procedures. A ready‐to‐use and stable patch, able to support airway functionality and tissue regeneration, remains a significant challenge. Here we present the development of an off‐the‐shelf composite patch consisting of a resorbable polymer to aid epithelial restoration and a 3D‐printed multimaterial structure to guarantee effective mechanical stability. To evaluate the prosthesis performance, we designed a pilot study on a large animal setting, monitoring postoperative survival and airway healing for up to 60 days. An anterior cervical tracheal defect was created on four domestic pigs and patched with the prosthesis. The results were satisfactory in terms of postoperative survival, as only one animal died before the end of the study. However, endoscopic findings revealed a worsening stenosis due to wound contraction, granulation tissue formation, and partial displacement of the prosthesis. These findings were confirmed at histology, where a prominent inflammatory infiltrate was evident. Blood tests performed during follow‐up did not reveal any systemic inflammatory reaction. Overall, we believe that further optimization of the prosthesis design and materials is necessary in order to create an ideal “off‐the‐shelf” tracheal substitute. Nevertheless, this pilot study provides promising results and novel insights into a clinically relevant research area.

Authors

Institutions

Publication Details

Journal
Bioengineering & Translational Medicine
Published
2026-01-27
DOI
https://doi.org/10.1002/btm2.70103
Primary Topic
Tracheal and airway disorders
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Use of a composite, 3D ‐printed patch as a partial airway replacement: A pilot study on the porcine model

Giovanna Brusatin, Marco Pietra, Domenico Ventrella, Noemi Romagnoli et al.
Bioengineering & Translational Medicine
Tracheal and airway disorders
article

Use of a composite, 3D ‐printed patch as a partial airway replacement: A pilot study on the porcine model

Giovanna Brusatin, Marco Pietra, Domenico Ventrella, Noemi Romagnoli, Alessandro Gandin, Alberto Elmi, Fiorella Calabrese, Giovanni Zambello, Margherita Pelosin, Maria Laura Bacci, Veronica Torresan, Federica Pezzuto, Marco Mammana, Federico Rea, Silvia Todros, Andrea Dell'Amore
article en

Abstract

Abstract Tracheal replacement is an unmet clinical need, as patients with long or complex airway defects are managed with tracheostomy or permanent stents. Experimental and clinical research is ongoing in order to find safe airway substitutes; however, the strategies under investigation suffer from major limitations, such as unsatisfactory re‐epithelialization, insufficient long‐term mechanical support, and complex ex vivo procedures. A ready‐to‐use and stable patch, able to support airway functionality and tissue regeneration, remains a significant challenge. Here we present the development of an off‐the‐shelf composite patch consisting of a resorbable polymer to aid epithelial restoration and a 3D‐printed multimaterial structure to guarantee effective mechanical stability. To evaluate the prosthesis performance, we designed a pilot study on a large animal setting, monitoring postoperative survival and airway healing for up to 60 days. An anterior cervical tracheal defect was created on four domestic pigs and patched with the prosthesis. The results were satisfactory in terms of postoperative survival, as only one animal died before the end of the study. However, endoscopic findings revealed a worsening stenosis due to wound contraction, granulation tissue formation, and partial displacement of the prosthesis. These findings were confirmed at histology, where a prominent inflammatory infiltrate was evident. Blood tests performed during follow‐up did not reveal any systemic inflammatory reaction. Overall, we believe that further optimization of the prosthesis design and materials is necessary in order to create an ideal “off‐the‐shelf” tracheal substitute. Nevertheless, this pilot study provides promising results and novel insights into a clinically relevant research area.

Bioengineering & Translational Medicine
University of Padua (IT), University of Bologna (IT)
European Commission, Università degli Studi di Padova, Fondazione Cassa di Risparmio di Verona Vicenza Belluno e Ancona, Regione del Veneto
Openalex Percentile: Top 78%
Tracheal and airway disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.