Validated LC‐MS/MS Method for Vibegron Quantification in Human Plasma via a Selective Fragment Ion ( <i>m</i> / <i>z</i> 135.1): Addressing Matrix Interference and Sample Instability

A sensitive and robust LC-MS/MS method was developed and validated for the quantification of vibegron in human plasma, employing electrospray ionization in positive mode and multiple reaction monitoring (MRM). The precursor ion m/z 445.5 yielded two product ions: m/z 427.4 and m/z 135.1. Despite higher intensity, m/z 427.4 was excluded due to chromatographic interference, while m/z 135.1, previously unreported for vibegron, was selected for its superior selectivity and specificity. A stable isotope-labeled internal standard, vibegron <sup>13</sup>C<sub>5</sub> (m/z 450.3 → 139.1), was used to enhance precision and minimize matrix effects. Chromatographic separation was achieved on a Kromasil C18 column with a mobile phase of acetonitrile and 10-mM ammonium formate (pH 5.8), yielding a retention time of 1.33 min and total runtime of 3.00 min. Liquid-liquid extraction with ethyl acetate provided consistent recovery (87.7%), and sodium fluoride was added to inhibit enzymatic degradation. The method demonstrated excellent linearity (0.500-400.223 ng/mL), precision (0.58%-3.34%), and accuracy (98.26%-102.29%), using only 100 μL of plasma. Fully compliant with ICH M10 guidelines, the method is well suited for future pharmacokinetic, bioavailability, and bioequivalence studies.

Authors

Institutions

Publication Details

Journal
Biomedical Chromatography
Published
2026-01-26
DOI
https://doi.org/10.1002/bmc.70363
Primary Topic
Pesticide Residue Analysis and Safety
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validated LC‐MS/MS Method for Vibegron Quantification in Human Plasma via a Selective Fragment Ion ( m / z 135.1): Addressing Matrix Interference and Sample Instability

Ashim Kumar Sen, Ujashkumar Shah, Santosh Tawari
Biomedical Chromatography
Pesticide Residue Analysis and Safety
article

Validated LC‐MS/MS Method for Vibegron Quantification in Human Plasma via a Selective Fragment Ion ( m / z 135.1): Addressing Matrix Interference and Sample Instability

Ashim Kumar Sen, Ujashkumar Shah, Santosh Tawari
article en

Abstract

A sensitive and robust LC-MS/MS method was developed and validated for the quantification of vibegron in human plasma, employing electrospray ionization in positive mode and multiple reaction monitoring (MRM). The precursor ion m/z 445.5 yielded two product ions: m/z 427.4 and m/z 135.1. Despite higher intensity, m/z 427.4 was excluded due to chromatographic interference, while m/z 135.1, previously unreported for vibegron, was selected for its superior selectivity and specificity. A stable isotope-labeled internal standard, vibegron <sup>13</sup>C<sub>5</sub> (m/z 450.3 → 139.1), was used to enhance precision and minimize matrix effects. Chromatographic separation was achieved on a Kromasil C18 column with a mobile phase of acetonitrile and 10-mM ammonium formate (pH 5.8), yielding a retention time of 1.33 min and total runtime of 3.00 min. Liquid-liquid extraction with ethyl acetate provided consistent recovery (87.7%), and sodium fluoride was added to inhibit enzymatic degradation. The method demonstrated excellent linearity (0.500-400.223 ng/mL), precision (0.58%-3.34%), and accuracy (98.26%-102.29%), using only 100 μL of plasma. Fully compliant with ICH M10 guidelines, the method is well suited for future pharmacokinetic, bioavailability, and bioequivalence studies.

Biomedical ChromatographyVol. 40(3)
Charotar University of Science and Technology (IN), Suamandeep Vidyapeeth University (IN), Sankalchand Patel University (IN)
Openalex Percentile: Top 78%
Pesticide Residue Analysis and Safety
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Validated LC‐MS/MS Method for Vibegron Quantification in Human Plasma via a Selective Fragment Ion ( <i>m</i> / <i>z</i> 135.1): Addressing Matrix Interference and Sample Instability — Ashim Kumar Sen, Ujashkumar Shah, et al. · Biomedical Chromatography (2026) | TGRS Research Map | TGRS