Polyvinyl Chloride-Based Coordination Polymer as Membrane for Phenol Detection

The investigation primarily focuses on synthesizing Polyvinyl Chloride (PVC)-coordination polymer (CP) polymeric membranes that employ L-Cu-NO3 (1∞[Cu3L2(NO3)]NO3·2MeOH·2H2O based on the Schiff base H2L, where H2L stands for N,N’-bis[(2-hydroxybenzilideneamino)-propyl]-piperazine)) as a coordination polymer. The membrane’s capacity to hold moisture is greatly improved by the addition of CPs. The water contact angle dropped from 73.4° for the PVC to about 71° for the composite membrane, indicating that the CP–PVC polymer interactions improved the hydrophilicity. Impedance spectroscopy (EIS) was used to determine the membranes response to the tested concentrations of phenol solution at pH 9.11 in the concentration range of 10−10 to 10−2 mol·L−1. A PVC membrane with a 0.6 wt% L-Cu-NO3 deposit on a Cu electrode yields the best response. Between 10−8 and 10−5 mol·L−1 phenol, a linear dependence was found. The detection limit was 4.64 × 10−8 mol·L−1.

Authors

Institutions

Publication Details

Journal
Processes
Published
2026-01-26
DOI
https://doi.org/10.3390/pr14030435
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Polyvinyl Chloride-Based Coordination Polymer as Membrane for Phenol Detection

Valentin Maranescu, Milica Tara-Lunga Mihali, Ildikó Buta, Nicoleta Pleşu et al.
Processes
Analytical Chemistry and Sensors
article

Polyvinyl Chloride-Based Coordination Polymer as Membrane for Phenol Detection

Valentin Maranescu, Milica Tara-Lunga Mihali, Ildikó Buta, Nicoleta Pleşu, Aurelia Visa, Alina Bora, Anemona-Mariana Cornea
article en

Abstract

The investigation primarily focuses on synthesizing Polyvinyl Chloride (PVC)-coordination polymer (CP) polymeric membranes that employ L-Cu-NO3 (1∞[Cu3L2(NO3)]NO3·2MeOH·2H2O based on the Schiff base H2L, where H2L stands for N,N’-bis[(2-hydroxybenzilideneamino)-propyl]-piperazine)) as a coordination polymer. The membrane’s capacity to hold moisture is greatly improved by the addition of CPs. The water contact angle dropped from 73.4° for the PVC to about 71° for the composite membrane, indicating that the CP–PVC polymer interactions improved the hydrophilicity. Impedance spectroscopy (EIS) was used to determine the membranes response to the tested concentrations of phenol solution at pH 9.11 in the concentration range of 10−10 to 10−2 mol·L−1. A PVC membrane with a 0.6 wt% L-Cu-NO3 deposit on a Cu electrode yields the best response. Between 10−8 and 10−5 mol·L−1 phenol, a linear dependence was found. The detection limit was 4.64 × 10−8 mol·L−1.

ProcessesVol. 14(3)
Polytechnic University of Timişoara (RO), Romanian Academy (RO)
European Regional Development Fund
Clean water and sanitation
Openalex Percentile: Top 80%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Polyvinyl Chloride-Based Coordination Polymer as Membrane for Phenol Detection — Valentin Maranescu, Milica Tara-Lunga Mihali, et al. · Processes (2026) | TGRS Research Map | TGRS