Recommendations for the integration of standardized quality indicators for glucose point-of-care testing

Objectives. Quality indicator (QI) monitoring is essential to quality assurance for point of care testing (POCT). QI standardization is needed in the POCT field to provide clear guidance to hospitals and produce National and International benchmarks. A central aim was to standardize POCT QIs with existing QIs of the MQI program recommended by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) for central laboratory testing for integration in Comparison programs. Material and methods. Process mapping and risk assessment of the POC glucose testing process were used to establish potential QI. Group consensus was used to rank each potential QI based on the ability to retrieve data for the specific QI. Higher scores were attributed to QI where data could be retrieved electronically and automatically. The highest scoring QI were chosen for follow-up. Members of the working group (authors) were asked to submit data from their own institutions for each QI to evaluate the feasibility of monitoring each QI and to develop preliminary benchmarks. Results. Five QI recommendations are provided for glucose POCT, including: positive patient identification, operator training, internal quality control monitoring, external quality assessment and critical results follow-up. Preliminary QI data are presented along with implementation strategies and challenges associated with each recommended QI. Conclusions. This study builds upon previous work by the Canadian Society of Clinical Chemists in developing a process to establish QIs for POCT based on process mapping and risk assessment. The recommended QIs are applicable to most other types of POCT, in addition to glucose testing.

Authors

Institutions

Publication Details

Journal
Laboratory Service
Published
2025-12-30
DOI
https://doi.org/10.17116/labs20251404133
Primary Topic
Clinical Laboratory Practices and Quality Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Recommendations for the integration of standardized quality indicators for glucose point-of-care testing

Michael J. Knauer, Anna Fuezery, Lyne Labrecque, Davor Brinc et al.
Laboratory Service
Clinical Laboratory Practices and Quality Control
article

Recommendations for the integration of standardized quality indicators for glucose point-of-care testing

Michael J. Knauer, Anna Fuezery, Lyne Labrecque, Davor Brinc, Miranda Brun, Sukhbir Kaur, WC Leung, Christine Collier, Ihssan Bouhtiany, P. Ip, A. Venner, E. Konstantin, Y. Huang, S. Arnoldo, J. Shaw, A. Fung, V. De Geer, V. Thakur
article en

Abstract

Objectives. Quality indicator (QI) monitoring is essential to quality assurance for point of care testing (POCT). QI standardization is needed in the POCT field to provide clear guidance to hospitals and produce National and International benchmarks. A central aim was to standardize POCT QIs with existing QIs of the MQI program recommended by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) for central laboratory testing for integration in Comparison programs. Material and methods. Process mapping and risk assessment of the POC glucose testing process were used to establish potential QI. Group consensus was used to rank each potential QI based on the ability to retrieve data for the specific QI. Higher scores were attributed to QI where data could be retrieved electronically and automatically. The highest scoring QI were chosen for follow-up. Members of the working group (authors) were asked to submit data from their own institutions for each QI to evaluate the feasibility of monitoring each QI and to develop preliminary benchmarks. Results. Five QI recommendations are provided for glucose POCT, including: positive patient identification, operator training, internal quality control monitoring, external quality assessment and critical results follow-up. Preliminary QI data are presented along with implementation strategies and challenges associated with each recommended QI. Conclusions. This study builds upon previous work by the Canadian Society of Clinical Chemists in developing a process to establish QIs for POCT based on process mapping and risk assessment. The recommended QIs are applicable to most other types of POCT, in addition to glucose testing.

Laboratory ServiceVol. 14(4)
Western University (CA), Memorial University of Newfoundland (CA), Sunnybrook Health Science Centre (CA), University Health Network (CA), University of British Columbia (CA), University of Ottawa (CA), University of Alberta (CA), University of Calgary (CA), University of Toronto (CA), Queen's University (CA), Saskatchewan Health Authority (CA), Health Sciences Centre (CA), Government of Newfoundland and Labrador (CA), Health Net (US), Canadian Electricity Association (CA), Memorial (RU), Newfoundland and Labrador Centre for Applied Health Research (CA), William Osler Health System (CA), Vitalité Health Network (CA), Université de Montréal (CA)
Partnerships for the goals
Openalex Percentile: Top 29%
Clinical Laboratory Practices and Quality Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.