New technologies for precise light field microscopy in high-resolution neuroimaging: Automated distortion calibration and correction algorithm

Objective: Light field microscopy (LFM) enables in vivo neuroimaging with high resolution and thus greatly pushes forward biomedical optical imaging research. Although continuous development of optical designs and computational reconstructions, inherent image distortion in LFM systems compromises spatial accuracy and image fidelity, posing a significant barrier to quantitative neuroscience applications. Existing distortion correction methods often rely on intricate, empirical-dependent calibration procedures or specific calibration targets, limiting their usability and scalability in practical settings. Methods: We introduce an automated distortion correction algorithm, namely AutoCalibrator-LFM, which utilizes a regular micro-lens-array pattern extracted from a simple fluorescence acrylic panel to realize distortion characterizations. Results: Leveraging the intrinsic structure encoded in raw light field data, this method enables precise geometric corrections without the need for external calibration phantoms or manual intervention. The algorithm is validated through extensive simulations and experimental studies involving both static and dynamic biological specimens. This method substantially reduces the alignment artifacts and improves the structural accuracy of reconstructed volumes. Notably, the distortion correction performance is comparable to that of expert manual calibration, while offering a faster and fully automated solution. Conclusion: AutoCalibrator-LFM makes LFM more accessible and precise and serves as a stepstone for future advanced image-processing algorithms and accurate LFM-based adaptive imaging pipelines in neuroscience. JOURNAL/atin/04.03/02274269-990000000-00024/inline-graphic1/v/2026-01-26T080410Z/r/image-tiff

Authors

Institutions

Publication Details

Journal
Advanced technology in neuroscience .
Published
2026-01-26
DOI
https://doi.org/10.4103/atn.atn-d-25-00024
Primary Topic
Digital Holography and Microscopy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

New technologies for precise light field microscopy in high-resolution neuroimaging: Automated distortion calibration and correction algorithm

Yuke Wang, Yuan Li, Zhi Lü
Advanced technology in neuroscience .
Digital Holography and Microscopy
article

New technologies for precise light field microscopy in high-resolution neuroimaging: Automated distortion calibration and correction algorithm

Yuke Wang, Yuan Li, Zhi Lü
article en

Abstract

Objective: Light field microscopy (LFM) enables in vivo neuroimaging with high resolution and thus greatly pushes forward biomedical optical imaging research. Although continuous development of optical designs and computational reconstructions, inherent image distortion in LFM systems compromises spatial accuracy and image fidelity, posing a significant barrier to quantitative neuroscience applications. Existing distortion correction methods often rely on intricate, empirical-dependent calibration procedures or specific calibration targets, limiting their usability and scalability in practical settings. Methods: We introduce an automated distortion correction algorithm, namely AutoCalibrator-LFM, which utilizes a regular micro-lens-array pattern extracted from a simple fluorescence acrylic panel to realize distortion characterizations. Results: Leveraging the intrinsic structure encoded in raw light field data, this method enables precise geometric corrections without the need for external calibration phantoms or manual intervention. The algorithm is validated through extensive simulations and experimental studies involving both static and dynamic biological specimens. This method substantially reduces the alignment artifacts and improves the structural accuracy of reconstructed volumes. Notably, the distortion correction performance is comparable to that of expert manual calibration, while offering a faster and fully automated solution. Conclusion: AutoCalibrator-LFM makes LFM more accessible and precise and serves as a stepstone for future advanced image-processing algorithms and accurate LFM-based adaptive imaging pipelines in neuroscience. JOURNAL/atin/04.03/02274269-990000000-00024/inline-graphic1/v/2026-01-26T080410Z/r/image-tiff

Advanced technology in neuroscience .
Tsinghua University (CN)
Openalex Percentile: Top 74%
Digital Holography and Microscopy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.