Engineering a High-Fidelity Neonatal Silicone Phantom: Development, Optimization, and User Evaluation of a 3D-Printed Vascular Access Model

Securing intravenous (IV) access in neonates is technically challenging due to extremely small vessel caliber, fragile skin, and limited subcutaneous tissue. High-fidelity training phantoms are essential for teaching ultrasound-guided vascular access, yet most commercial models are adult-sized, lack neonatal realism, and are cost-prohibitive. The aim of this study was to design and optimize a low-cost, ultrasound-compatible 3D silicone phantom that replicates neonatal tissue and vasculature for peripheral and central IV access training. A multi-phase design process incorporated 3D-printed polylactic acid (PLA) molds, Dragon Skin™ silicone (Smooth-On, Inc., Macungie, PA, USA), Slacker® softener (Smooth-On, Inc., Macungie, PA, USA), and 3% talcum powder to enhance echogenicity. Silicone tubing (0.2-0.4 mm internal diameters (ID)) was embedded at neonatal-appropriate depths using rotational casting for dermal uniformity and vessel channel supports for positional accuracy. Iterative engineering improved dermal wall uniformity, vessel stability, and ultrasound visibility, resulting in a durable, reproducible phantom with realistic tissue compliance and vessel compressibility. The developed 3D silicone phantom provides a realistic, affordable, and reproducible neonatal vascular access simulator. User feedback supports its fidelity and utility, and its low material cost enables broad implementation in neonatal procedural training programs.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2026-01-26
DOI
https://doi.org/10.7759/cureus.102315
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Engineering a High-Fidelity Neonatal Silicone Phantom: Development, Optimization, and User Evaluation of a 3D-Printed Vascular Access Model

Shaylin D Zoellner, Aarnav Parikh, Aneesha Morris, Pratik Parikh
Cureus
Central Venous Catheters and Hemodialysis
article

Engineering a High-Fidelity Neonatal Silicone Phantom: Development, Optimization, and User Evaluation of a 3D-Printed Vascular Access Model

Shaylin D Zoellner, Aarnav Parikh, Aneesha Morris, Pratik Parikh
article en

Abstract

Securing intravenous (IV) access in neonates is technically challenging due to extremely small vessel caliber, fragile skin, and limited subcutaneous tissue. High-fidelity training phantoms are essential for teaching ultrasound-guided vascular access, yet most commercial models are adult-sized, lack neonatal realism, and are cost-prohibitive. The aim of this study was to design and optimize a low-cost, ultrasound-compatible 3D silicone phantom that replicates neonatal tissue and vasculature for peripheral and central IV access training. A multi-phase design process incorporated 3D-printed polylactic acid (PLA) molds, Dragon Skin™ silicone (Smooth-On, Inc., Macungie, PA, USA), Slacker® softener (Smooth-On, Inc., Macungie, PA, USA), and 3% talcum powder to enhance echogenicity. Silicone tubing (0.2-0.4 mm internal diameters (ID)) was embedded at neonatal-appropriate depths using rotational casting for dermal uniformity and vessel channel supports for positional accuracy. Iterative engineering improved dermal wall uniformity, vessel stability, and ultrasound visibility, resulting in a durable, reproducible phantom with realistic tissue compliance and vessel compressibility. The developed 3D silicone phantom provides a realistic, affordable, and reproducible neonatal vascular access simulator. User feedback supports its fidelity and utility, and its low material cost enables broad implementation in neonatal procedural training programs.

CureusVol. 18(1)
San Antonio College (US), Baylor College of Medicine (US), University of the Incarnate Word (US)
Openalex Percentile: Top 80%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Engineering a High-Fidelity Neonatal Silicone Phantom: Development, Optimization, and User Evaluation of a 3D-Printed Vascular Access Model — Shaylin D Zoellner, Aarnav Parikh, et al. · Cureus (2026) | TGRS Research Map | TGRS