Assessment of organ-specific radiation dose reduction by integrated shielding configuration in mammography: a Monte Carlo simulation and experimental validation study

Scatter radiation to out-of-field radiosensitive organs such as the eyes, thyroid, and axilla can contribute to peripheral dose during mammography. This study evaluates an integrated shielding configuration designed to reduce such exposure. A high-density lead-glass face guard (LG-FG) and a hybrid compression paddle with stainless steel (HCSS-paddle) were modelled in MCNPX using Mo/Mo spectra at 25-35 kV under craniocaudal (CC) geometry. Simulation outputs were validated using optically stimulated luminescent dosimeters (OSLDs) and thermoluminescent dosimeter-100 (TLD-100) measurements on an anthropomorphic phantom. Both simulation and measurement showed consistent peripheral organ dose reductions of approximately ~85%-95% in the eyes, thyroid, and axilla, with modest change in compressed-breast dose (⩽10%-12%) and torso dose (⩽5%). Simulation-measurement differences remained within the predefined ±10% equivalence margin, indicating strong agreement between Monte Carlo predictions and phantom measurements.

Authors

Institutions

Publication Details

Journal
Journal of Radiological Protection
Published
2026-01-26
DOI
https://doi.org/10.1088/1361-6498/ae3d42
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of organ-specific radiation dose reduction by integrated shielding configuration in mammography: a Monte Carlo simulation and experimental validation study

Kyutae Jeon
Journal of Radiological Protection
Radiation Dose and Imaging
article

Assessment of organ-specific radiation dose reduction by integrated shielding configuration in mammography: a Monte Carlo simulation and experimental validation study

Kyutae Jeon
article en

Abstract

Scatter radiation to out-of-field radiosensitive organs such as the eyes, thyroid, and axilla can contribute to peripheral dose during mammography. This study evaluates an integrated shielding configuration designed to reduce such exposure. A high-density lead-glass face guard (LG-FG) and a hybrid compression paddle with stainless steel (HCSS-paddle) were modelled in MCNPX using Mo/Mo spectra at 25-35 kV under craniocaudal (CC) geometry. Simulation outputs were validated using optically stimulated luminescent dosimeters (OSLDs) and thermoluminescent dosimeter-100 (TLD-100) measurements on an anthropomorphic phantom. Both simulation and measurement showed consistent peripheral organ dose reductions of approximately ~85%-95% in the eyes, thyroid, and axilla, with modest change in compressed-breast dose (⩽10%-12%) and torso dose (⩽5%). Simulation-measurement differences remained within the predefined ±10% equivalence margin, indicating strong agreement between Monte Carlo predictions and phantom measurements.

Journal of Radiological ProtectionVol. 46(1)
Chungnam National University (KR)
Openalex Percentile: Top 79%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Assessment of organ-specific radiation dose reduction by integrated shielding configuration in mammography: a Monte Carlo simulation and experimental validation study — Kyutae Jeon · Journal of Radiological Protection (2026) | TGRS Research Map | TGRS