Wearable ECG-PPG Deep Learning Model for Cardiac Index-Based Noninvasive Cardiac Output Estimation in Cardiac Surgery Patients

Accurate cardiac output (CO) measurement is vital for hemodynamic management; however, it usually requires invasive monitoring, which limits its continuous and out-of-hospital use. Wearable sensors integrated with deep learning offer a noninvasive alternative. This study developed and validated a lightweight deep learning model using wearable electrocardiography (ECG) and photoplethysmography (PPG) signals to predict CO and examined whether cardiac index-based normalization (Cardiac Index (CI) = CO/body surface area) improves performance. Twenty-seven patients who underwent cardiac surgery and had pulmonary artery catheters were prospectively enrolled. Single-lead ECG (HiCardi+ chest patch) and finger PPG (WristOx2 3150) were recorded simultaneously and processed through an ECG-PPG fusion network with cross-modal interaction. Three models were trained as follows: (1) CI prediction, (2) direct CO prediction, and (3) indirect CO prediction. The total number of CO = predicted CI × body surface area. Reference values were derived from thermodilution. The CI model achieved the best performance, and the indirect CO model showed significant reductions in error/agreement metrics (MAE/RMSE/bias; <i>p</i> < 0.0001), while correlation-based metrics are reported descriptively without implying statistical significance. The Pearson correlation coefficient (PCC) and percentage error (PE) for the indirect CO estimates (PCC = 0.904; PE = 23.75%). The indirect CO estimates met the predefined PE < 30% agreement benchmark for method-comparison; this is not a universal clinical standard. These results demonstrate that wearable ECG-PPG fusion deep learning can achieve accurate, noninvasive CO estimation and that CI-based normalization enhances model agreement with pulmonary artery catheter measurements, supporting continuous catheter-free hemodynamic monitoring.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-01-22
DOI
https://doi.org/10.3390/s26020735
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wearable ECG-PPG Deep Learning Model for Cardiac Index-Based Noninvasive Cardiac Output Estimation in Cardiac Surgery Patients

S. H. Cho, Sarah Soh, Junghwan Park, Kyung Soo Chung et al.
Sensors
Hemodynamic Monitoring and Therapy
article

Wearable ECG-PPG Deep Learning Model for Cardiac Index-Based Noninvasive Cardiac Output Estimation in Cardiac Surgery Patients

S. H. Cho, Sarah Soh, Junghwan Park, Kyung Soo Chung, Min Dong Sung, Minwoo Kim, Jimyeoung Jung, Hyun Chel Joo
article en

Abstract

Accurate cardiac output (CO) measurement is vital for hemodynamic management; however, it usually requires invasive monitoring, which limits its continuous and out-of-hospital use. Wearable sensors integrated with deep learning offer a noninvasive alternative. This study developed and validated a lightweight deep learning model using wearable electrocardiography (ECG) and photoplethysmography (PPG) signals to predict CO and examined whether cardiac index-based normalization (Cardiac Index (CI) = CO/body surface area) improves performance. Twenty-seven patients who underwent cardiac surgery and had pulmonary artery catheters were prospectively enrolled. Single-lead ECG (HiCardi+ chest patch) and finger PPG (WristOx2 3150) were recorded simultaneously and processed through an ECG-PPG fusion network with cross-modal interaction. Three models were trained as follows: (1) CI prediction, (2) direct CO prediction, and (3) indirect CO prediction. The total number of CO = predicted CI × body surface area. Reference values were derived from thermodilution. The CI model achieved the best performance, and the indirect CO model showed significant reductions in error/agreement metrics (MAE/RMSE/bias; <i>p</i> < 0.0001), while correlation-based metrics are reported descriptively without implying statistical significance. The Pearson correlation coefficient (PCC) and percentage error (PE) for the indirect CO estimates (PCC = 0.904; PE = 23.75%). The indirect CO estimates met the predefined PE < 30% agreement benchmark for method-comparison; this is not a universal clinical standard. These results demonstrate that wearable ECG-PPG fusion deep learning can achieve accurate, noninvasive CO estimation and that CI-based normalization enhances model agreement with pulmonary artery catheter measurements, supporting continuous catheter-free hemodynamic monitoring.

SensorsVol. 26(2)
Yonsei University (KR), Daewoo Pharma (South Korea) (KR)
Openalex Percentile: Top 77%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.