Classification of faults in transmission line with penetration of WDG using ANN

• Proposed an ANN-based model for fault classification in wind-integrated grids • Voltage signals at PCC used for training and testing under 1,200 fault cases • Achieved 95.6% classification accuracy for line-to-line (L–L) fault detection • Model demonstrates robustness under varying wind penetration conditions • Supports SDG 7 by improving renewable-integrated transmission line reliability Distributed generation (DG) plays a key role in addressing the increasing power demand within modern power systems. The integration of distributed generators into the grid raises several concerns about power system structure regulation and protection. The increasing penetration of wind-based distributed generation challenges conventional fault detection techniques in transmission systems. Even after years of extensive research, fault classification continues to be one of the most important difficulties among the several fault concerns that arise in a distributed generation integrated transmission line. To prevent financial losses, researchers are working to identify and analyze these problems at the earliest. This paper attempts to examine the type of fault that occurred in the Wind-Integrated Transmission Lines. This study proposes Artificial neural network-based techniques to identify transmission line faults in the presence of Wind distributed generation (WDG). The voltage signal as an input for artificial neural network (ANN) is taken out at the point of common connection (PCC). Training and testing are performed using the extracted data, with 70% allocated for training and 30% for testing. Faults in the simulated model are classified using an ANN technique. To model and simulate the proposed WDG integration approach, the MATLAB/Simulink environment is utilized. The findings are then examined and compared with and without penetration of WDG. The proposed model achieved 95.6% classification accuracy for L-L fault across 1,200 fault scenarios. This supports Sustainable Development Goals (SDG) 7 by improving protection reliability in renewable-integrated grids.

Authors

Institutions

Publication Details

Journal
Results in Engineering
Published
2026-01-26
DOI
https://doi.org/10.1016/j.rineng.2026.109292
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Classification of faults in transmission line with penetration of WDG using ANN

Sonora Dixit, Ahlem Fatnassi, Soorya Prakash Shukla, Basanta K. Panigrahi et al.
Results in Engineering
Power Systems Fault Detection
article

Classification of faults in transmission line with penetration of WDG using ANN

Sonora Dixit, Ahlem Fatnassi, Soorya Prakash Shukla, Basanta K. Panigrahi, Aymen Flah, Mohammad Ghatasheh, Tarek Salem Abdennaji, Abhishek Kumar Tripathi
article en

Abstract

• Proposed an ANN-based model for fault classification in wind-integrated grids • Voltage signals at PCC used for training and testing under 1,200 fault cases • Achieved 95.6% classification accuracy for line-to-line (L–L) fault detection • Model demonstrates robustness under varying wind penetration conditions • Supports SDG 7 by improving renewable-integrated transmission line reliability Distributed generation (DG) plays a key role in addressing the increasing power demand within modern power systems. The integration of distributed generators into the grid raises several concerns about power system structure regulation and protection. The increasing penetration of wind-based distributed generation challenges conventional fault detection techniques in transmission systems. Even after years of extensive research, fault classification continues to be one of the most important difficulties among the several fault concerns that arise in a distributed generation integrated transmission line. To prevent financial losses, researchers are working to identify and analyze these problems at the earliest. This paper attempts to examine the type of fault that occurred in the Wind-Integrated Transmission Lines. This study proposes Artificial neural network-based techniques to identify transmission line faults in the presence of Wind distributed generation (WDG). The voltage signal as an input for artificial neural network (ANN) is taken out at the point of common connection (PCC). Training and testing are performed using the extracted data, with 70% allocated for training and 30% for testing. Faults in the simulated model are classified using an ANN technique. To model and simulate the proposed WDG integration approach, the MATLAB/Simulink environment is utilized. The findings are then examined and compared with and without penetration of WDG. The proposed model achieved 95.6% classification accuracy for L-L fault across 1,200 fault scenarios. This supports Sustainable Development Goals (SDG) 7 by improving protection reliability in renewable-integrated grids.

Results in EngineeringVol. 29
Northern Border University (SA), VSB - Technical University of Ostrava (CZ), Siksha O Anusandhan University (IN), Indian Institute of Technology Bhilai (IN), Aditya Birla (India) (IN), University of Business and Technology (SA), Middle East University (JO)
Openalex Percentile: Top 77%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.