Zero-Sequence Current Limitation of Parallel-Laid HV Cable Sheathing Based on Phase Sequence Optimization

Parallel laying of high-voltage cables will generate a zero-sequence current, due to spatial electromagnetic induction, which reduces the cable’s current-carrying capacity, causing heating and corrosion of the grounding points and deteriorating grounding performance. Currently, there is a lack of effective control measures. This article establishes a calculation model for the cable sheath current under the condition of double circuit cable cross interconnection grounding, analyzes the causes of a zero-sequence grounding current in a double circuit cable sheath, and proposes an optimal phase sequence selection method, considering load changes with the goal of maximizing the probability of the cable sheath current, not exceeding the standard. The results show that when the double circuit cable is evenly distributed in the cross interconnection section, the zero-sequence grounding current will be generated on the metal sheath of the cable, causing an excessive total grounding current. By applying the proposed probability-based phase-sequence optimization, the likelihood that both circuits simultaneously satisfy the sheath-current criterion can be significantly improved; for example, under representative layouts and load distributions, the “both-within-limit” probability can reach 53.3% (horizontal layout), 76.2% (horizontal equilateral triangle layout), 90.5% (vertical layout), and 81.6% (vertical equilateral triangle layout). For different working conditions, selecting the optimal load phase sequence combination by maximizing the probability of the sheath current and not exceeding the standard within the current carrying area can help to reduce the cable sheath current.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2026-01-26
DOI
https://doi.org/10.3390/electronics15030523
Primary Topic
Thermal Analysis in Power Transmission
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Zero-Sequence Current Limitation of Parallel-Laid HV Cable Sheathing Based on Phase Sequence Optimization

Fengrun Wang, Zhihui Zheng, Junping Cao, Keren Shao et al.
Electronics
Thermal Analysis in Power Transmission
article

Zero-Sequence Current Limitation of Parallel-Laid HV Cable Sheathing Based on Phase Sequence Optimization

Fengrun Wang, Zhihui Zheng, Junping Cao, Keren Shao, Hailiang Lu, Zhiyi Gao, Yu Ma
article en

Abstract

Parallel laying of high-voltage cables will generate a zero-sequence current, due to spatial electromagnetic induction, which reduces the cable’s current-carrying capacity, causing heating and corrosion of the grounding points and deteriorating grounding performance. Currently, there is a lack of effective control measures. This article establishes a calculation model for the cable sheath current under the condition of double circuit cable cross interconnection grounding, analyzes the causes of a zero-sequence grounding current in a double circuit cable sheath, and proposes an optimal phase sequence selection method, considering load changes with the goal of maximizing the probability of the cable sheath current, not exceeding the standard. The results show that when the double circuit cable is evenly distributed in the cross interconnection section, the zero-sequence grounding current will be generated on the metal sheath of the cable, causing an excessive total grounding current. By applying the proposed probability-based phase-sequence optimization, the likelihood that both circuits simultaneously satisfy the sheath-current criterion can be significantly improved; for example, under representative layouts and load distributions, the “both-within-limit” probability can reach 53.3% (horizontal layout), 76.2% (horizontal equilateral triangle layout), 90.5% (vertical layout), and 81.6% (vertical equilateral triangle layout). For different working conditions, selecting the optimal load phase sequence combination by maximizing the probability of the sheath current and not exceeding the standard within the current carrying area can help to reduce the cable sheath current.

ElectronicsVol. 15(3)
State Grid Corporation of China (China) (CN), Wuhan University (CN), Wuchang University of Technology (CN), Shanghai Electric (China) (CN)
State Grid Zhejiang Electric Power Company
Affordable and clean energy
Openalex Percentile: Top 77%
Thermal Analysis in Power Transmission
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.