Simulated Oxygen Supply Efficiency Assessment to Represent Stored Red Blood Cells Quality

Hemolysis rate is usually used as the acceptance criterion for stored red blood cells (RBCs) in clinical practice. However, there is a current lack of parameters for the characterization of hemoglobin quality. This study aimed to incorporate oxygen affinity, cooperativity, and the Bohr effect into a parameter system to monitor oxygen supply efficiency in stored RBCs, potentially serving as a basis for quality assessment. Han Chinese blood from plains, Tibetan blood from plateau, bovine hemoglobin (bHb), and a dextran-bovine hemoglobin conjugate (Dex20-bHb) were analyzed using the BLOODOX-2018. Oxygen affinity (P<sub>50</sub>) was determined by oxygen dissociation curves (ODCs) at pH = 7.4. Cooperativity was assessed through the Hill coefficient, calculated from the fitting range of the Hill equation. The Bohr effect was evaluated by the acid-base sensitivity index (SI) under simulated pH conditions of the lungs (pH = 7.6) and tissues (pH = 7.2) to calculate corresponding P<sub>50</sub> values. Oxygen partial pressures (PO<sub>2</sub>) simulating lungs (PO<sub>2</sub> = 100 mmHg for plains and 60 mmHg for plateau) and tissues (PO<sub>2</sub> = 40 mmHg for plains and 30 mmHg for plateau) were used to calculate theoretical oxygen-release capacities in both environments. Multiple regression analysis explored relationships among parameters, constructing a system to assess changes in rat RBCs during storage. Optimized test methods determined P<sub>50</sub>, Hill coefficient, SI, and theoretical oxygen-release capacities for Han Chinese blood, Tibetan blood, bHb, and Dex20-bHb samples in various environments. We constructed a parameter system to characterize blood's oxygen supply efficiency, revealing the significant influence of the Bohr effect. This influence varied with environmental changes in oxygen affinity. We validated the system using stored rat RBCs, finding consistent P<sub>50</sub> trends with predictions, and initial increases in Hill coefficient and SI followed by decreases. Theoretical oxygen-release capacities varied significantly between plateau and plain environments. These results support using oxygen supply efficiency to assess RBC storage quality for developing transfusion strategies. P<sub>50</sub>, Hill coefficient, SI, and theoretical oxygen-release capacity in different environments can be incorporated into blood oxygen supply efficiency characterization systems to assess the quality changes in RBCs during storage.

Authors

Institutions

Publication Details

Journal
Life
Published
2026-01-26
DOI
https://doi.org/10.3390/life16020205
Primary Topic
Blood transfusion and management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulated Oxygen Supply Efficiency Assessment to Represent Stored Red Blood Cells Quality

Weidan Li, Zongtang Chu, Peilin Shu, Guoxing You et al.
Life
Blood transfusion and management
article

Simulated Oxygen Supply Efficiency Assessment to Represent Stored Red Blood Cells Quality

Weidan Li, Zongtang Chu, Peilin Shu, Guoxing You, Dong Qin, Ying Wang, Lian Zhao, Hong Zhou
article en

Abstract

Hemolysis rate is usually used as the acceptance criterion for stored red blood cells (RBCs) in clinical practice. However, there is a current lack of parameters for the characterization of hemoglobin quality. This study aimed to incorporate oxygen affinity, cooperativity, and the Bohr effect into a parameter system to monitor oxygen supply efficiency in stored RBCs, potentially serving as a basis for quality assessment. Han Chinese blood from plains, Tibetan blood from plateau, bovine hemoglobin (bHb), and a dextran-bovine hemoglobin conjugate (Dex20-bHb) were analyzed using the BLOODOX-2018. Oxygen affinity (P<sub>50</sub>) was determined by oxygen dissociation curves (ODCs) at pH = 7.4. Cooperativity was assessed through the Hill coefficient, calculated from the fitting range of the Hill equation. The Bohr effect was evaluated by the acid-base sensitivity index (SI) under simulated pH conditions of the lungs (pH = 7.6) and tissues (pH = 7.2) to calculate corresponding P<sub>50</sub> values. Oxygen partial pressures (PO<sub>2</sub>) simulating lungs (PO<sub>2</sub> = 100 mmHg for plains and 60 mmHg for plateau) and tissues (PO<sub>2</sub> = 40 mmHg for plains and 30 mmHg for plateau) were used to calculate theoretical oxygen-release capacities in both environments. Multiple regression analysis explored relationships among parameters, constructing a system to assess changes in rat RBCs during storage. Optimized test methods determined P<sub>50</sub>, Hill coefficient, SI, and theoretical oxygen-release capacities for Han Chinese blood, Tibetan blood, bHb, and Dex20-bHb samples in various environments. We constructed a parameter system to characterize blood's oxygen supply efficiency, revealing the significant influence of the Bohr effect. This influence varied with environmental changes in oxygen affinity. We validated the system using stored rat RBCs, finding consistent P<sub>50</sub> trends with predictions, and initial increases in Hill coefficient and SI followed by decreases. Theoretical oxygen-release capacities varied significantly between plateau and plain environments. These results support using oxygen supply efficiency to assess RBC storage quality for developing transfusion strategies. P<sub>50</sub>, Hill coefficient, SI, and theoretical oxygen-release capacity in different environments can be incorporated into blood oxygen supply efficiency characterization systems to assess the quality changes in RBCs during storage.

LifeVol. 16(2)
Academy of Military Medical Sciences (CN)
Openalex Percentile: Top 78%
Blood transfusion and management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.