Calibration of Low-Cost Sensors for PM10 and PM2.5 Based on Artificial Intelligence for Smart Cities

Exposure to Particulate Matter (PM) is linked to respiratory and cardiovascular diseases, certain types of cancer, and accounts for approximately seven million premature deaths globally. While governments and organizations have implemented various strategies for Air Quality (AQ) such as the deployment of Air Quality Monitoring Networks (AQMN), these networks often suffer from limited spatial coverage and involve high installation and maintenance costs. Consequently, the implementation of networks based on Low-Cost Sensors (LCS) has emerged as a viable alternative. Nevertheless, LCS systems have certain drawbacks, such as lower reading precision, which can be mitigated through specific calibration models and methods. This paper presents the results and conclusions derived from simultaneous PM<sub>10</sub> and PM<sub>2.5</sub> monitoring comparisons between LCS nodes and a T640X reference sensor. Additionally, Relative Humidity (RH), temperature, and absorption flow measurements were collected via an Automet meteorological station. The monitoring equipment was installed at the Faculty of Environment of the Universidad Distrital in Bogotá. The LCS calibration process began with data preprocessing, which involved filtering, segmentation, and the application of FastDTW. Subsequently, calibration was performed using a variety of models, including two statistical approaches, three Machine Learning algorithms, and one Deep Learning model. The findings highlight the critical importance of applying FastDTW during preprocessing and the necessity of incorporating RH, temperature, and absorption flow factors to enhance accuracy. Furthermore, the study concludes that Random Forest and XGBoost offered the highest performance among the methods evaluated. While satellites map city-wide patterns and MAX-DOAS enables hourly source attribution, our calibrated LCS network supplies continuous, street-scale data at low CAPEX/OPEX-forming a practical backbone for sustained micro-scale monitoring in Bogotá.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-01-25
DOI
https://doi.org/10.3390/s26030796
Primary Topic
Air Quality Monitoring and Forecasting
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calibration of Low-Cost Sensors for PM10 and PM2.5 Based on Artificial Intelligence for Smart Cities

Ricardo Santiago Gomez, Roberto Ferro, José Rodríguez
Sensors
Air Quality Monitoring and Forecasting
article

Calibration of Low-Cost Sensors for PM10 and PM2.5 Based on Artificial Intelligence for Smart Cities

Ricardo Santiago Gomez, Roberto Ferro, José Rodríguez
article en

Abstract

Exposure to Particulate Matter (PM) is linked to respiratory and cardiovascular diseases, certain types of cancer, and accounts for approximately seven million premature deaths globally. While governments and organizations have implemented various strategies for Air Quality (AQ) such as the deployment of Air Quality Monitoring Networks (AQMN), these networks often suffer from limited spatial coverage and involve high installation and maintenance costs. Consequently, the implementation of networks based on Low-Cost Sensors (LCS) has emerged as a viable alternative. Nevertheless, LCS systems have certain drawbacks, such as lower reading precision, which can be mitigated through specific calibration models and methods. This paper presents the results and conclusions derived from simultaneous PM<sub>10</sub> and PM<sub>2.5</sub> monitoring comparisons between LCS nodes and a T640X reference sensor. Additionally, Relative Humidity (RH), temperature, and absorption flow measurements were collected via an Automet meteorological station. The monitoring equipment was installed at the Faculty of Environment of the Universidad Distrital in Bogotá. The LCS calibration process began with data preprocessing, which involved filtering, segmentation, and the application of FastDTW. Subsequently, calibration was performed using a variety of models, including two statistical approaches, three Machine Learning algorithms, and one Deep Learning model. The findings highlight the critical importance of applying FastDTW during preprocessing and the necessity of incorporating RH, temperature, and absorption flow factors to enhance accuracy. Furthermore, the study concludes that Random Forest and XGBoost offered the highest performance among the methods evaluated. While satellites map city-wide patterns and MAX-DOAS enables hourly source attribution, our calibrated LCS network supplies continuous, street-scale data at low CAPEX/OPEX-forming a practical backbone for sustained micro-scale monitoring in Bogotá.

SensorsVol. 26(3)
Universidad Distrital Francisco José de Caldas (CO), Escuela Colombiana de Carreras Industriales (CO)
Sustainable cities and communities
Openalex Percentile: Top 80%
Air Quality Monitoring and Forecasting
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.