Computed tomography and 3D visualization in forensic shooting distance estimation – A ballistic gelatine pilot study

Accurate estimation of shooting distance is one of the main aspects in forensic gunshot case reconstruction. Reliable methods to estimate shooting distance are thus important for forensic practitioners. In this pilot study we test how computed tomography (CT) based evaluation of bullet cavitation could potentially be utilized to differentiate shooting distance. To conduct our study, we utilized ballistic gelatine blocks as a soft tissue simulant. Test shooting was performed from two distances, 20 and 100 m. Four expanding monolithic bullets were used all in 0.30 caliber (Barnes TTSX, Sako Blade, Norma Ecostrike, Lapua Naturalis). The gelatine blocks were CT-scanned after the experiment. The scans were processed and segmented using an open-source 3D Slicer software to provide a 3D reconstruction of the cavitation and obtain numerical cavitation parameters (total volume and surface area of cavitation; maximum crack diameter; location of maximum cavitation). Our results indicated that all four bullets had distinct terminal ballistic performance. This could be detected from the bullet parameters such as maximum diameter and also from the pattern of cavitation. Shooting distance had a consistent, measurable association with bullet diameter and surface area of the gelatine cavity in all four bullets. Our preliminary pilot study underscores the potential of CT in the comprehensive analysis of gelatine cavitation in terminal ballistics. Our results suggest that it would be essential to know exact bullet type when shooting distance is estimated from terminal ballistic findings.

Authors

Institutions

Publication Details

Journal
Legal Medicine
Published
2026-01-25
DOI
https://doi.org/10.1016/j.legalmed.2026.102799
Primary Topic
Traumatic Ocular and Foreign Body Injuries
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Computed tomography and 3D visualization in forensic shooting distance estimation – A ballistic gelatine pilot study

Timo Liimatainen, Niinimäki Jaakko, Eveliina Lammentausta, Mikael Brix et al.
Legal Medicine
Traumatic Ocular and Foreign Body Injuries
article

Computed tomography and 3D visualization in forensic shooting distance estimation – A ballistic gelatine pilot study

Timo Liimatainen, Niinimäki Jaakko, Eveliina Lammentausta, Mikael Brix, Alina Junno, Petteri Oura, Juha Kiljunen, Juho-Antti Junno
article en

Abstract

Accurate estimation of shooting distance is one of the main aspects in forensic gunshot case reconstruction. Reliable methods to estimate shooting distance are thus important for forensic practitioners. In this pilot study we test how computed tomography (CT) based evaluation of bullet cavitation could potentially be utilized to differentiate shooting distance. To conduct our study, we utilized ballistic gelatine blocks as a soft tissue simulant. Test shooting was performed from two distances, 20 and 100 m. Four expanding monolithic bullets were used all in 0.30 caliber (Barnes TTSX, Sako Blade, Norma Ecostrike, Lapua Naturalis). The gelatine blocks were CT-scanned after the experiment. The scans were processed and segmented using an open-source 3D Slicer software to provide a 3D reconstruction of the cavitation and obtain numerical cavitation parameters (total volume and surface area of cavitation; maximum crack diameter; location of maximum cavitation). Our results indicated that all four bullets had distinct terminal ballistic performance. This could be detected from the bullet parameters such as maximum diameter and also from the pattern of cavitation. Shooting distance had a consistent, measurable association with bullet diameter and surface area of the gelatine cavity in all four bullets. Our preliminary pilot study underscores the potential of CT in the comprehensive analysis of gelatine cavitation in terminal ballistics. Our results suggest that it would be essential to know exact bullet type when shooting distance is estimated from terminal ballistic findings.

Legal MedicineVol. 81
National Bureau of Investigation (FI), Oulu University Hospital (FI), Oulu University of Applied Sciences (FI), University of Oulu (FI)
Openalex Percentile: Top 78%
Traumatic Ocular and Foreign Body Injuries
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.