Water Filtration Machine with Monitoring System for Aquades Production and Founding an Optimal Pre- treatment Filter Ratio Before Reverse Osmosis Membrane

The increasing demand for distilled water (Aquades) in pharmaceutical and medical applications contrasts sharply with the limited quality of municipal water supplies and the high operating costs of commercial Aquades procurement. At the same time, many small-scale facilities still lack integrated systems capable of meeting the Indonesian Ministry of Health standard (Permenkes RI No. 32/2017). Existing research on reverse osmosis (RO) systems largely focuses on membrane or filtration performance, with limited attention to real-time water-quality monitoring and systematic optimization of pre-treatment filters. This study develops an integrated filtration and monitoring system designed to ensure regulatory compliance while optimizing the composition of pre-treatment materials. The system combines silica sand, activated carbon, and zeolite pre-filters with RO, supported by six analog sensors that continuously monitor pH, turbidity, and Total Dissolved Solids before and after filtration. Validation results show high sensor accuracy, with 99.77% for TDS, 98.10% for pH, and 99.97% for turbidity. Among six tested filter compositions, the 25% silica sand-25% activated carbon-50% zeolite configuration achieves the highest average filtration efficiency of 88.96%. These findings demonstrate that optimized pre-treatment combined with real-time monitoring can significantly improve RO performance and support cost-effective Aquades production for medical use.

Authors

Institutions

Publication Details

Journal
Journal of ICT Research and Applications
Published
2025-12-31
DOI
https://doi.org/10.5614/itbj.ict.res.appl.2025.19.2.4
Primary Topic
Water Quality Monitoring Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Water Filtration Machine with Monitoring System for Aquades Production and Founding an Optimal Pre- treatment Filter Ratio Before Reverse Osmosis Membrane

Ahmad Fauzan Adziimaa, Muhamad Sultan Rasyiid
Journal of ICT Research and Applications
Water Quality Monitoring Technologies
article

Water Filtration Machine with Monitoring System for Aquades Production and Founding an Optimal Pre- treatment Filter Ratio Before Reverse Osmosis Membrane

Ahmad Fauzan Adziimaa, Muhamad Sultan Rasyiid
article en

Abstract

The increasing demand for distilled water (Aquades) in pharmaceutical and medical applications contrasts sharply with the limited quality of municipal water supplies and the high operating costs of commercial Aquades procurement. At the same time, many small-scale facilities still lack integrated systems capable of meeting the Indonesian Ministry of Health standard (Permenkes RI No. 32/2017). Existing research on reverse osmosis (RO) systems largely focuses on membrane or filtration performance, with limited attention to real-time water-quality monitoring and systematic optimization of pre-treatment filters. This study develops an integrated filtration and monitoring system designed to ensure regulatory compliance while optimizing the composition of pre-treatment materials. The system combines silica sand, activated carbon, and zeolite pre-filters with RO, supported by six analog sensors that continuously monitor pH, turbidity, and Total Dissolved Solids before and after filtration. Validation results show high sensor accuracy, with 99.77% for TDS, 98.10% for pH, and 99.97% for turbidity. Among six tested filter compositions, the 25% silica sand-25% activated carbon-50% zeolite configuration achieves the highest average filtration efficiency of 88.96%. These findings demonstrate that optimized pre-treatment combined with real-time monitoring can significantly improve RO performance and support cost-effective Aquades production for medical use.

Journal of ICT Research and ApplicationsVol. 19(2)
Sepuluh Nopember Institute of Technology (ID)
Institut Teknologi Sepuluh Nopember
Clean water and sanitation
Openalex Percentile: Top 33%
Water Quality Monitoring Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.