Dean migration mechanisms: facilitating the control of microbial contaminants in cell therapy product manufacturing

Cell therapy products are rapidly transforming clinical practice, but their short shelf-lives and inability to undergo terminal sterilization create major challenges for sterility testing. Conventional rapid microbiological methods (RMMs) are hindered by the dense cellular background of therapeutic samples, which masks rare microbial contaminants and necessitates pre-analytical processing. Efficient separation of microorganisms from high-density cell suspensions is therefore a critical prerequisite for enabling real-time, in-process sterility assurance. Here, we systematically elucidate the Dean flow-dominated migration mechanism and determine its effective range for continuous, label-free separation of non-typical contaminants ≤ 5 μm in microchannels exceeding 40 μm in height. We demonstrate that particles with ap/h < 0.05 undergo exclusive Dean-induced lateral migration, while those near the inertial focusing threshold (ap/h ≈ 0.07) exhibit a Reynolds number-dependent transition between unfocused and centerline-focused streams. Leveraging these principles, we designed optimized channel geometries that achieved > 95% separation efficiency and > 96% purity of T cells versus three morphologically distinct bacteria at 10⁵ bacteria/mL. At ultra-low loads (< 10 CFU/mL), culture-based assays confirmed 100% detection for inocula > 1 CFU/mL. Our findings validate Dean migration as a governing mechanism for submicron particle separation and provide a path toward integrating microfluidic modules into closed CAR-T manufacturing platforms, advancing real-time microbial quality control in cell therapy production.

Authors

Institutions

Publication Details

Journal
Microsystems & Nanoengineering
Published
2026-01-26
DOI
https://doi.org/10.1038/s41378-025-01043-w
Primary Topic
Microfluidic and Bio-sensing Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dean migration mechanisms: facilitating the control of microbial contaminants in cell therapy product manufacturing

Li Zhou, Junjie Huang, Liang Xu, Weizhao Yao et al.
Microsystems & Nanoengineering
Microfluidic and Bio-sensing Technologies
article

Dean migration mechanisms: facilitating the control of microbial contaminants in cell therapy product manufacturing

Li Zhou, Junjie Huang, Liang Xu, Weizhao Yao, Ming Zhao, Junhao Tan, Jianbo Yang, Ziming Huang, Chengshun Shen
article en

Abstract

Cell therapy products are rapidly transforming clinical practice, but their short shelf-lives and inability to undergo terminal sterilization create major challenges for sterility testing. Conventional rapid microbiological methods (RMMs) are hindered by the dense cellular background of therapeutic samples, which masks rare microbial contaminants and necessitates pre-analytical processing. Efficient separation of microorganisms from high-density cell suspensions is therefore a critical prerequisite for enabling real-time, in-process sterility assurance. Here, we systematically elucidate the Dean flow-dominated migration mechanism and determine its effective range for continuous, label-free separation of non-typical contaminants ≤ 5 μm in microchannels exceeding 40 μm in height. We demonstrate that particles with ap/h < 0.05 undergo exclusive Dean-induced lateral migration, while those near the inertial focusing threshold (ap/h ≈ 0.07) exhibit a Reynolds number-dependent transition between unfocused and centerline-focused streams. Leveraging these principles, we designed optimized channel geometries that achieved > 95% separation efficiency and > 96% purity of T cells versus three morphologically distinct bacteria at 10⁵ bacteria/mL. At ultra-low loads (< 10 CFU/mL), culture-based assays confirmed 100% detection for inocula > 1 CFU/mL. Our findings validate Dean migration as a governing mechanism for submicron particle separation and provide a path toward integrating microfluidic modules into closed CAR-T manufacturing platforms, advancing real-time microbial quality control in cell therapy production.

Microsystems & NanoengineeringVol. 12(1)
Tianjin University (CN), Chinese Academy of Sciences (CN), Hangzhou Academy of Agricultural Sciences (CN), Tianjin Medical University (CN)
National Natural Science Foundation of China, Chinese Academy of Sciences, Tianjin University, Chinese Academy of Engineering
Openalex Percentile: Top 78%
Microfluidic and Bio-sensing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.