Composite‐Field Annealing Enables Superior High‐Temperature Noise Stability in Fluxgate Sensors With Co‐Rich Amorphous Microwires

ABSTRACT Fluxgate sensors with Co‐rich amorphous microwires, widely used for their low noise in magnetic field measurements, encounter significant challenges in high‐temperature environments such as well drilling and geological exploration. Prolonged thermal aging degrades the performance of Co‐rich amorphous microwires, resulting in increased noise levels. To address these issues, this study innovatively proposed a composite‐field annealing (CFA)—a sequential treatment involving tensile stress annealing, followed by longitudinal and transverse magnetic field annealing processes—to enhance the thermal aging stability of Co‐rich amorphous microwires. A sensor incorporating CFA‐aged microwires achieved a significantly lower noise level of 18 pT Hz −1/2 at 1 Hz, compared to 130 pT Hz −1/2 in normally annealed (NA) counterparts. CFA microwires exhibited superior long‐term stability in permeability, with a lower rate of 34.2% of permeability variation over time at 175°C for 150 h. The enhanced stability was attributed to the stabilization of magnetic anisotropy for CFA microwires, as confirmed by higher activation energy calculated by local magnetic anisotropy energy during aging and a negligible domain wall movement rate under in situ high‐temperature Lorentz transmission electron microscopy (L‐TEM) experiments. This work introduces CFA as a critical technique for optimizing Co‐rich amorphous microwires, enabling the development of high‐stability and low‐noise fluxgate sensors for harsh environmental applications.

Authors

Institutions

Publication Details

Journal
Rare Metals
Published
2025-12-26
DOI
https://doi.org/10.1002/rar2.70093
Primary Topic
Magnetic Field Sensors Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Composite‐Field Annealing Enables Superior High‐Temperature Noise Stability in Fluxgate Sensors With Co‐Rich Amorphous Microwires

Qikui Man, Min Su, Lizi Pan, Baogen Shen et al.
Rare Metals
Magnetic Field Sensors Techniques
article

Composite‐Field Annealing Enables Superior High‐Temperature Noise Stability in Fluxgate Sensors With Co‐Rich Amorphous Microwires

Qikui Man, Min Su, Lizi Pan, Baogen Shen, Aina He, Chunyang Mu, Yaqiang Dong, Xingjie Jia, Zhen Cui, Jiawei Li, Lining Pan
article en

Abstract

ABSTRACT Fluxgate sensors with Co‐rich amorphous microwires, widely used for their low noise in magnetic field measurements, encounter significant challenges in high‐temperature environments such as well drilling and geological exploration. Prolonged thermal aging degrades the performance of Co‐rich amorphous microwires, resulting in increased noise levels. To address these issues, this study innovatively proposed a composite‐field annealing (CFA)—a sequential treatment involving tensile stress annealing, followed by longitudinal and transverse magnetic field annealing processes—to enhance the thermal aging stability of Co‐rich amorphous microwires. A sensor incorporating CFA‐aged microwires achieved a significantly lower noise level of 18 pT Hz −1/2 at 1 Hz, compared to 130 pT Hz −1/2 in normally annealed (NA) counterparts. CFA microwires exhibited superior long‐term stability in permeability, with a lower rate of 34.2% of permeability variation over time at 175°C for 150 h. The enhanced stability was attributed to the stabilization of magnetic anisotropy for CFA microwires, as confirmed by higher activation energy calculated by local magnetic anisotropy energy during aging and a negligible domain wall movement rate under in situ high‐temperature Lorentz transmission electron microscopy (L‐TEM) experiments. This work introduces CFA as a critical technique for optimizing Co‐rich amorphous microwires, enabling the development of high‐stability and low‐noise fluxgate sensors for harsh environmental applications.

Rare MetalsVol. 45(2)
Lanzhou University of Technology (CN), Hengdian Group DMEGC Magnetics (China) (CN), Ningbo Institute of Industrial Technology (CN)
National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities
Openalex Percentile: Top 38%
Magnetic Field Sensors Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.