Artifact Mimicking Mechanical Valve Dysfunction on Intraoperative Transesophageal Echocardiography Following Redo Mitral Valve Replacement

Intraoperative transesophageal echocardiography (TEE) is vital for assessing prosthetic valve function, but imaging artifacts can lead to misdiagnosis. We describe a case of a 54-year-old man who underwent redo mitral valve replacement with a mechanical prosthesis, in which intraoperative TEE suggested prosthetic leaflet immobility. This prompted surgical re-exploration, which revealed normal valve function. Despite resection of posterior leaflet remnants that may have caused leaflet immobility, the abnormal findings persisted on TEE but were ultimately shown to be artifacts on intraoperative fluoroscopy. This case highlights the potential for TEE artifacts to mimic mechanical valve dysfunction. Multimodal imaging is critical for accurate diagnosis and avoiding unnecessary re-intervention.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2026-01-22
DOI
https://doi.org/10.7759/cureus.102096
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Artifact Mimicking Mechanical Valve Dysfunction on Intraoperative Transesophageal Echocardiography Following Redo Mitral Valve Replacement

Suguru Tatsuki, Gentaku Hama, R Koushima, McAndrew Merlini et al.
Cureus
Cardiac Valve Diseases and Treatments
article

Artifact Mimicking Mechanical Valve Dysfunction on Intraoperative Transesophageal Echocardiography Following Redo Mitral Valve Replacement

Suguru Tatsuki, Gentaku Hama, R Koushima, McAndrew Merlini, Keijiro Mitube
article en

Abstract

Intraoperative transesophageal echocardiography (TEE) is vital for assessing prosthetic valve function, but imaging artifacts can lead to misdiagnosis. We describe a case of a 54-year-old man who underwent redo mitral valve replacement with a mechanical prosthesis, in which intraoperative TEE suggested prosthetic leaflet immobility. This prompted surgical re-exploration, which revealed normal valve function. Despite resection of posterior leaflet remnants that may have caused leaflet immobility, the abnormal findings persisted on TEE but were ultimately shown to be artifacts on intraoperative fluoroscopy. This case highlights the potential for TEE artifacts to mimic mechanical valve dysfunction. Multimodal imaging is critical for accurate diagnosis and avoiding unnecessary re-intervention.

CureusVol. 18(1)
Sapporo Science Center (JP)
Openalex Percentile: Top 80%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Artifact Mimicking Mechanical Valve Dysfunction on Intraoperative Transesophageal Echocardiography Following Redo Mitral Valve Replacement — Suguru Tatsuki, Gentaku Hama, et al. · Cureus (2026) | TGRS Research Map | TGRS