An Investigation of Cracks in PK-Section Concrete Beams at Early Ages

Early age cracking induced by cement hydration heat in a 37.6 m-wide PK-section concrete box girder was investigated through full-scale field testing and numerical simulation. Material properties, temperature, and strain were measured, and the obtained thermal and mechanical parameters were used to simulate temperature and stress distributions during cantilever casting. Results show that direct casting on the foundation cap led to extensive vertical cracking in diaphragms, where tensile stresses exceeded concrete strength, corresponding to a cracking index of approximately 1.8, with thermal-to-shrinkage stress ratios up to 3:1 in critical regions. Under cantilever construction conditions, significant transverse stress occurred only at the diaphragm bottom, reaching a cracking index of about 1.6, with a thermal-to-shrinkage ratio of 2:1. Reducing casting temperature lowered thermal stress by 0.1 MPa/°C, while adding 0.9 kg/m3 polypropylene fibers increased early-age tensile strength by 15%. Optimized mix design or the inclusion of mineral admixtures such as silica fume further reduced shrinkage. The combined application of these measures effectively mitigated early-age cracking risk, providing practical guidance for the construction of wide-box girders in subtropical climates.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-01-22
DOI
https://doi.org/10.3390/buildings16020460
Primary Topic
Concrete Properties and Behavior
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Investigation of Cracks in PK-Section Concrete Beams at Early Ages

Zepeng Zhang, Bin Huang, Hongsheng Li, Xuefei SHI et al.
Buildings
Concrete Properties and Behavior
article

An Investigation of Cracks in PK-Section Concrete Beams at Early Ages

Zepeng Zhang, Bin Huang, Hongsheng Li, Xuefei SHI, Jia Wang
article en

Abstract

Early age cracking induced by cement hydration heat in a 37.6 m-wide PK-section concrete box girder was investigated through full-scale field testing and numerical simulation. Material properties, temperature, and strain were measured, and the obtained thermal and mechanical parameters were used to simulate temperature and stress distributions during cantilever casting. Results show that direct casting on the foundation cap led to extensive vertical cracking in diaphragms, where tensile stresses exceeded concrete strength, corresponding to a cracking index of approximately 1.8, with thermal-to-shrinkage stress ratios up to 3:1 in critical regions. Under cantilever construction conditions, significant transverse stress occurred only at the diaphragm bottom, reaching a cracking index of about 1.6, with a thermal-to-shrinkage ratio of 2:1. Reducing casting temperature lowered thermal stress by 0.1 MPa/°C, while adding 0.9 kg/m3 polypropylene fibers increased early-age tensile strength by 15%. Optimized mix design or the inclusion of mineral admixtures such as silica fume further reduced shrinkage. The combined application of these measures effectively mitigated early-age cracking risk, providing practical guidance for the construction of wide-box girders in subtropical climates.

BuildingsVol. 16(2)
Tongji University (CN), Guangzhou Automobile Group (China) (CN)
Climate action
Openalex Percentile: Top 79%
Concrete Properties and Behavior
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.