Impact of Device Non-Ideality on Respiratory Oscillometry Measures

Oscillometry is increasingly used for diagnosing respiratory conditions by measuring the respiratory system mechanical impedance. To minimize misdiagnosis, the accuracy of the measures and the factors that may impair it need to be fully investigated. Mathematical models are a useful tool for simulating measurements in various known conditions, providing information to evaluate the effect of different devices or processing methods on measurement accuracy. Previous studies demonstrated that signal processing methods impact the results of oscillometry measurements. However, the impact of the oscillometry device input resistance has not been analyzed. This work presents a mathematical model of the oscillometry device coupled with the patient's respiratory system to evaluate the impact of the device input resistance on measurement accuracy in infants. In this study, the model is used to generate synthetic oscillometry data using real breathing patterns and varying device resistance. We processed the simulated data to calculate respiratory system resistance and reactance using a least-mean-squares method. The results were compared with the resistance and reactance values used in the model. The error averaged over different real breathing patterns was proven to be influenced by the increase in the device resistance, both in linear and quadratic terms. When considering real newborns' breathing patterns, to maintain a mean and maximum error on resistance and reactance below 10<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">%</sup>- as per the published technical standards for in-vitro tests - we found that the device resistance must be lower than or equal to 2 <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$cmH_{2}O\cdot s/\mathrm{L}$</tex>. The developed model can be useful in the development of device requirements for accurate measurements.

Authors

Institutions

Publication Details

Published
2025-10-22
DOI
https://doi.org/10.1109/metroxraine66377.2025.11340236
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Device Non-Ideality on Respiratory Oscillometry Measures

R. L. Dellacà, C. Veneroni, Elena Barzanti
Non-Invasive Vital Sign Monitoring
article

Impact of Device Non-Ideality on Respiratory Oscillometry Measures

R. L. Dellacà, C. Veneroni, Elena Barzanti
article en

Abstract

Oscillometry is increasingly used for diagnosing respiratory conditions by measuring the respiratory system mechanical impedance. To minimize misdiagnosis, the accuracy of the measures and the factors that may impair it need to be fully investigated. Mathematical models are a useful tool for simulating measurements in various known conditions, providing information to evaluate the effect of different devices or processing methods on measurement accuracy. Previous studies demonstrated that signal processing methods impact the results of oscillometry measurements. However, the impact of the oscillometry device input resistance has not been analyzed. This work presents a mathematical model of the oscillometry device coupled with the patient's respiratory system to evaluate the impact of the device input resistance on measurement accuracy in infants. In this study, the model is used to generate synthetic oscillometry data using real breathing patterns and varying device resistance. We processed the simulated data to calculate respiratory system resistance and reactance using a least-mean-squares method. The results were compared with the resistance and reactance values used in the model. The error averaged over different real breathing patterns was proven to be influenced by the increase in the device resistance, both in linear and quadratic terms. When considering real newborns' breathing patterns, to maintain a mean and maximum error on resistance and reactance below 10<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">%</sup>- as per the published technical standards for in-vitro tests - we found that the device resistance must be lower than or equal to 2 <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$cmH_{2}O\cdot s/\mathrm{L}$</tex>. The developed model can be useful in the development of device requirements for accurate measurements.

Politecnico di Milano (IT)
Openalex Percentile: Top 39%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Impact of Device Non-Ideality on Respiratory Oscillometry Measures — R. L. Dellacà, C. Veneroni, et al. · (2025) | TGRS Research Map | TGRS