Mechanical performance of sustainable concrete containing industrial waste admixtures of SF, FA, CCI, and crushed quartz at different water–binder ratios

The present study examined the mechanical performance of sustainable concrete with silica fume (SF), fly ash (FA), cooled cast iron (CCI), and crushed quartz powder (CQ) used as partial cement replacements at three water-to-binder ratios (0.36, 0.41, and 0.46). Fifteen concrete mixtures were cast and tested for compressive, splitting tensile, and flexural strengths at 7, 28, and 90 days. Results indicated that the lowest water-binder ratio of 0.36 produced the highest strengths, consistent with values of 78 MPa compressive strength at 28 days and 87.8 MPa at 90 days, which were better than those obtained from mixes having the other two ratios by up to 34% in early ages and by up to 33% in later ages. The partial replacement of SF by FA lowered the early-age strength, but very significant long-term gains were recorded; replacing three-quarters of SF with FA increased the 90-day compressive strength by 5.9%, 30.4%, and 30.1% for groups 0.36, 0.41, and 0.46, respectively, compared to their corresponding mixes with SF only. Incorporating CQ led to reductions in strength at 28 days of 9.3-13.4%; however, reductions at 90 days remained modest, 8.1-13.6%, indicating improved long-term pozzolanic contributions. It is noted that tensile-to-compressive strength ratios for all mixtures ranged from 9.8 to 12.2%, and flexural-to-compressive ratios ranged from 13.6 to 14.7%, which are better than the ACI318 predictive correlations for concretes using industrial by-products. The results confirm that optimized SCM blending higher fly-ash proportions at lower water-binder ratios enhances long-term mechanical performance while enabling significant cement reduction, supporting more environmentally sustainable high-strength concrete.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-01-22
DOI
https://doi.org/10.1038/s41598-025-34612-0
Primary Topic
Concrete and Cement Materials Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mechanical performance of sustainable concrete containing industrial waste admixtures of SF, FA, CCI, and crushed quartz at different water–binder ratios

Mohamed Khalifa Bneni, Seleem S. E. Ahmad, Abdo-Alfatah A A Graf
Scientific Reports
Concrete and Cement Materials Research
article

Mechanical performance of sustainable concrete containing industrial waste admixtures of SF, FA, CCI, and crushed quartz at different water–binder ratios

Mohamed Khalifa Bneni, Seleem S. E. Ahmad, Abdo-Alfatah A A Graf
article en

Abstract

The present study examined the mechanical performance of sustainable concrete with silica fume (SF), fly ash (FA), cooled cast iron (CCI), and crushed quartz powder (CQ) used as partial cement replacements at three water-to-binder ratios (0.36, 0.41, and 0.46). Fifteen concrete mixtures were cast and tested for compressive, splitting tensile, and flexural strengths at 7, 28, and 90 days. Results indicated that the lowest water-binder ratio of 0.36 produced the highest strengths, consistent with values of 78 MPa compressive strength at 28 days and 87.8 MPa at 90 days, which were better than those obtained from mixes having the other two ratios by up to 34% in early ages and by up to 33% in later ages. The partial replacement of SF by FA lowered the early-age strength, but very significant long-term gains were recorded; replacing three-quarters of SF with FA increased the 90-day compressive strength by 5.9%, 30.4%, and 30.1% for groups 0.36, 0.41, and 0.46, respectively, compared to their corresponding mixes with SF only. Incorporating CQ led to reductions in strength at 28 days of 9.3-13.4%; however, reductions at 90 days remained modest, 8.1-13.6%, indicating improved long-term pozzolanic contributions. It is noted that tensile-to-compressive strength ratios for all mixtures ranged from 9.8 to 12.2%, and flexural-to-compressive ratios ranged from 13.6 to 14.7%, which are better than the ACI318 predictive correlations for concretes using industrial by-products. The results confirm that optimized SCM blending higher fly-ash proportions at lower water-binder ratios enhances long-term mechanical performance while enabling significant cement reduction, supporting more environmentally sustainable high-strength concrete.

Scientific ReportsVol. 16(1)
Sebha University (LY), Zagazig University (EG), Al Zawiya University (LY)
Responsible consumption and production
Openalex Percentile: Top 80%
Concrete and Cement Materials Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.