Resistance of Trapezoidal Sheeting in Fire

Abstract Cold‐formed steel trapezoidal sheeting has a significant decrease of its bending resistance in fire due to the small sheet thickness. The bending resistance is generally reached within 10 minutes of a fire. However, the failure in bending is followed by transitions from bending behaviour to a catenary action. The catenary action can form only if a horizontal support is provided by fasteners to the supporting structure. The fasteners are therefore a critical component of the structural design and usually determine the load capacity of the sheeting in fire. In the presented study, connection tests at both normal and elevated temperature are conducted using two different types of fasteners: self‐drilling screws with washers and powder‐actuated fasteners. For each tested temperature (20, 350, 500, 600 and 700 °C) and sheet thickness (0.75 and 1.5 mm), 4 tests were conducted. The results provide insights into the behaviour of these connections at both normal and elevated temperatures. This paper also describes a large‐scale fire test of a lightweight roof with trapezoidal sheeting. Fastening with self‐drilling screws was used. The fire test consists of two simple beams with a span of 2x4 m and focuses on fastening and the behaviour of a roof above an internal support. Fire test resulted in a failure of the sheeting connection.

Authors

Institutions

Publication Details

Journal
ce/papers
Published
2025-12-01
DOI
https://doi.org/10.1002/cepa.70128
Primary Topic
Fire effects on concrete materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Resistance of Trapezoidal Sheeting in Fire

Michal Jandera, Aleš Chovanec
ce/papers
Fire effects on concrete materials
article

Resistance of Trapezoidal Sheeting in Fire

Michal Jandera, Aleš Chovanec
article en

Abstract

Abstract Cold‐formed steel trapezoidal sheeting has a significant decrease of its bending resistance in fire due to the small sheet thickness. The bending resistance is generally reached within 10 minutes of a fire. However, the failure in bending is followed by transitions from bending behaviour to a catenary action. The catenary action can form only if a horizontal support is provided by fasteners to the supporting structure. The fasteners are therefore a critical component of the structural design and usually determine the load capacity of the sheeting in fire. In the presented study, connection tests at both normal and elevated temperature are conducted using two different types of fasteners: self‐drilling screws with washers and powder‐actuated fasteners. For each tested temperature (20, 350, 500, 600 and 700 °C) and sheet thickness (0.75 and 1.5 mm), 4 tests were conducted. The results provide insights into the behaviour of these connections at both normal and elevated temperatures. This paper also describes a large‐scale fire test of a lightweight roof with trapezoidal sheeting. Fastening with self‐drilling screws was used. The fire test consists of two simple beams with a span of 2x4 m and focuses on fastening and the behaviour of a roof above an internal support. Fire test resulted in a failure of the sheeting connection.

ce/papersVol. 8(6)
Czech Technical University in Prague (CZ)
Sustainable cities and communities
Openalex Percentile: Top 33%
Fire effects on concrete materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.