Statistical process control of CBCT density gamma analysis as a clinical trigger for offline adaptive radiotherapy
<i>Objective.</i>Adaptive radiotherapy aimed to account for inter- and intra-fractional anatomical changes to improve target coverage and spare normal tissues. Commercial softwares could quantify anatomical and setup differences between planning computed tomography (pCT) and image-guidance cone-beam computed tomography (CBCT) using density gamma passing rate (dGPR). This study evaluated the utility of dGPR as an automated, site-specific trigger for offline adaptive workflows, using statistical process control (SPC) to define tolerance thresholds and correlating dGPR with setup errors, planning target volume (PTV) coverage, and longitudinal stability.<i>Approach.</i>240 patients across six anatomical sites were retrospectively analysed. First-fraction CBCTs were compared to pCTs using MobiusCB to compute dGPR. SPC analysis was performed to establish site-specific tolerance limits. Rigid phantom studies were conducted to quantify dGPR sensitivity to setup errors. Correlation between dGPR and PTV<i>V</i><sub>100%</sub>was assessed in patients with repeat CTs, and longitudinal stability of dGPR across fractions was evaluated.<i>Main results.</i>SPC-derived lower action limits (Al) ranged from 97.3% (brain) to 82.2% (breast), reflecting site-specific anatomical variability and imaging protocols. Phantom studies verified dGPR sensitivity due to rigid shifts, with head dGPR decreasing to as low as 83.5% at 8 mm translation, while pelvis dGPR remained above 93.2% for the same shift, reflecting greater tolerance due to its larger volume. In head-and-neck patients, dGPR correlated moderately with changes in PTV<i>V</i><sub>100%</sub>(<i>r</i>= 0.56), with no coverage losses >10% observed when dGPR exceeded 90%. Longitudinal analysis showed stable dGPR for most sites, but gradual declines in head-and-neck patients, with some values falling below SPC-derived threshold of 94.3% towards the end of treatment.<i>Significance.</i>dGPR offered a practical, automated, and site-specific metric for detecting anatomical changes and setup errors during radiotherapy. SPC-derived thresholds provided robust action levels tailored to each site, and MobiusCB enabled automated alerts when thresholds were exceeded, reducing reliance on subjective image inspection.
Authors
- Calvin Wei Yang Koh (ORCID: https://orcid.org/0000-0002-6434-2400)
- James Cheow Lei Lee
- Melvin Ming Long Chew
- Hong Qi Tan (ORCID: https://orcid.org/0000-0001-7878-4544)
- Yun Ming Wong (ORCID: https://orcid.org/0000-0002-1564-2087)
- Ping Lin Yeap (ORCID: https://orcid.org/0009-0004-0061-5889)
- Clifford Ghee Ann Chua (ORCID: https://orcid.org/0000-0002-6887-7015)
- Kang Hao Lee
- Geoffvinc Ng
Institutions
- Nanyang Technological University (SG)
- University of Cambridge (GB)
- Duke-NUS Medical School (SG)
- National Cancer Centre Singapore (SG)
Publication Details
- Journal
- Physics in Medicine and Biology
- Published
- 2026-01-22
- DOI
- https://doi.org/10.1088/1361-6560/ae3c55
- Primary Topic
- Advanced Radiotherapy Techniques
- Type
- article
- Field-Weighted Citation Impact
- 0.00