Statistical process control of CBCT density gamma analysis as a clinical trigger for offline adaptive radiotherapy

<i>Objective.</i>Adaptive radiotherapy aimed to account for inter- and intra-fractional anatomical changes to improve target coverage and spare normal tissues. Commercial softwares could quantify anatomical and setup differences between planning computed tomography (pCT) and image-guidance cone-beam computed tomography (CBCT) using density gamma passing rate (dGPR). This study evaluated the utility of dGPR as an automated, site-specific trigger for offline adaptive workflows, using statistical process control (SPC) to define tolerance thresholds and correlating dGPR with setup errors, planning target volume (PTV) coverage, and longitudinal stability.<i>Approach.</i>240 patients across six anatomical sites were retrospectively analysed. First-fraction CBCTs were compared to pCTs using MobiusCB to compute dGPR. SPC analysis was performed to establish site-specific tolerance limits. Rigid phantom studies were conducted to quantify dGPR sensitivity to setup errors. Correlation between dGPR and PTV<i>V</i><sub>100%</sub>was assessed in patients with repeat CTs, and longitudinal stability of dGPR across fractions was evaluated.<i>Main results.</i>SPC-derived lower action limits (Al) ranged from 97.3% (brain) to 82.2% (breast), reflecting site-specific anatomical variability and imaging protocols. Phantom studies verified dGPR sensitivity due to rigid shifts, with head dGPR decreasing to as low as 83.5% at 8 mm translation, while pelvis dGPR remained above 93.2% for the same shift, reflecting greater tolerance due to its larger volume. In head-and-neck patients, dGPR correlated moderately with changes in PTV<i>V</i><sub>100%</sub>(<i>r</i>= 0.56), with no coverage losses >10% observed when dGPR exceeded 90%. Longitudinal analysis showed stable dGPR for most sites, but gradual declines in head-and-neck patients, with some values falling below SPC-derived threshold of 94.3% towards the end of treatment.<i>Significance.</i>dGPR offered a practical, automated, and site-specific metric for detecting anatomical changes and setup errors during radiotherapy. SPC-derived thresholds provided robust action levels tailored to each site, and MobiusCB enabled automated alerts when thresholds were exceeded, reducing reliance on subjective image inspection.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2026-01-22
DOI
https://doi.org/10.1088/1361-6560/ae3c55
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Statistical process control of CBCT density gamma analysis as a clinical trigger for offline adaptive radiotherapy

Calvin Wei Yang Koh, James Cheow Lei Lee, Melvin Ming Long Chew, Hong Qi Tan et al.
Physics in Medicine and Biology
Advanced Radiotherapy Techniques
article

Statistical process control of CBCT density gamma analysis as a clinical trigger for offline adaptive radiotherapy

Calvin Wei Yang Koh, James Cheow Lei Lee, Melvin Ming Long Chew, Hong Qi Tan, Yun Ming Wong, Ping Lin Yeap, Clifford Ghee Ann Chua, Kang Hao Lee, Geoffvinc Ng
article en

Abstract

<i>Objective.</i>Adaptive radiotherapy aimed to account for inter- and intra-fractional anatomical changes to improve target coverage and spare normal tissues. Commercial softwares could quantify anatomical and setup differences between planning computed tomography (pCT) and image-guidance cone-beam computed tomography (CBCT) using density gamma passing rate (dGPR). This study evaluated the utility of dGPR as an automated, site-specific trigger for offline adaptive workflows, using statistical process control (SPC) to define tolerance thresholds and correlating dGPR with setup errors, planning target volume (PTV) coverage, and longitudinal stability.<i>Approach.</i>240 patients across six anatomical sites were retrospectively analysed. First-fraction CBCTs were compared to pCTs using MobiusCB to compute dGPR. SPC analysis was performed to establish site-specific tolerance limits. Rigid phantom studies were conducted to quantify dGPR sensitivity to setup errors. Correlation between dGPR and PTV<i>V</i><sub>100%</sub>was assessed in patients with repeat CTs, and longitudinal stability of dGPR across fractions was evaluated.<i>Main results.</i>SPC-derived lower action limits (Al) ranged from 97.3% (brain) to 82.2% (breast), reflecting site-specific anatomical variability and imaging protocols. Phantom studies verified dGPR sensitivity due to rigid shifts, with head dGPR decreasing to as low as 83.5% at 8 mm translation, while pelvis dGPR remained above 93.2% for the same shift, reflecting greater tolerance due to its larger volume. In head-and-neck patients, dGPR correlated moderately with changes in PTV<i>V</i><sub>100%</sub>(<i>r</i>= 0.56), with no coverage losses >10% observed when dGPR exceeded 90%. Longitudinal analysis showed stable dGPR for most sites, but gradual declines in head-and-neck patients, with some values falling below SPC-derived threshold of 94.3% towards the end of treatment.<i>Significance.</i>dGPR offered a practical, automated, and site-specific metric for detecting anatomical changes and setup errors during radiotherapy. SPC-derived thresholds provided robust action levels tailored to each site, and MobiusCB enabled automated alerts when thresholds were exceeded, reducing reliance on subjective image inspection.

Physics in Medicine and BiologyVol. 71(3)
Nanyang Technological University (SG), University of Cambridge (GB), Duke-NUS Medical School (SG), National Cancer Centre Singapore (SG)
Openalex Percentile: Top 79%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.