Influence of Layer Thickness on the Detection of Plastic Films Using Optical Photothermal Infrared Spectroscopy (O-PTIR)

This study investigates how varying film thickness affects the qualitative identifiability of plastics using optical photothermal infrared spectroscopy (O-PTIR) on examples of common plastics such as polyamide 6 (PA6) and polyethylene terephthalate (PET). The main methodology consists of applying a thin layer of PA6 and PET separately to each substrate, namely, PET to polyethylene (PE) and PA6 to polypropylene (PP), and reducing the thickness of the coatings until the O-PTIR signal of the film is no longer detectable. As expected, the characteristic O-PTIR signal for PA and PET decreased with a decreasing film thickness. However, the results show that the O-PTIR detection limit for the plastics could not be reached, as the characteristic peaks of the substrate plastics are still clearly visible at a layer thickness of approximately 0.18 μm for PET and approximately 0.29 μm for PA6. These are the minimum stable film thicknesses that could be achieved since the selected film production process (drop deposition process) does not allow for thinner layers. As this work is a feasibility study, further factors influencing the O-PTIR measurement of plastic films should be investigated in a subsequent work.

Authors

Institutions

Publication Details

Journal
ACS Measurement Science Au
Published
2026-01-22
DOI
https://doi.org/10.1021/acsmeasuresciau.5c00149
Primary Topic
Thermography and Photoacoustic Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of Layer Thickness on the Detection of Plastic Films Using Optical Photothermal Infrared Spectroscopy (O-PTIR)

Florian Bittner, Madina Shamsuyeva, Jan Fridtjof Häusler
ACS Measurement Science Au
Thermography and Photoacoustic Techniques
article

Influence of Layer Thickness on the Detection of Plastic Films Using Optical Photothermal Infrared Spectroscopy (O-PTIR)

Florian Bittner, Madina Shamsuyeva, Jan Fridtjof Häusler
article en

Abstract

This study investigates how varying film thickness affects the qualitative identifiability of plastics using optical photothermal infrared spectroscopy (O-PTIR) on examples of common plastics such as polyamide 6 (PA6) and polyethylene terephthalate (PET). The main methodology consists of applying a thin layer of PA6 and PET separately to each substrate, namely, PET to polyethylene (PE) and PA6 to polypropylene (PP), and reducing the thickness of the coatings until the O-PTIR signal of the film is no longer detectable. As expected, the characteristic O-PTIR signal for PA and PET decreased with a decreasing film thickness. However, the results show that the O-PTIR detection limit for the plastics could not be reached, as the characteristic peaks of the substrate plastics are still clearly visible at a layer thickness of approximately 0.18 μm for PET and approximately 0.29 μm for PA6. These are the minimum stable film thicknesses that could be achieved since the selected film production process (drop deposition process) does not allow for thinner layers. As this work is a feasibility study, further factors influencing the O-PTIR measurement of plastic films should be investigated in a subsequent work.

ACS Measurement Science AuVol. 6(1)
Leibniz University Hannover (DE)
Openalex Percentile: Top 80%
Thermography and Photoacoustic Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.