Alternative Seismic Design for Six Storey Concentrically Braced Frames

Abstract The present paper intends to illustrate the main advantages and disadvantages of four alternative seismic deign procedures for concentrically braced frames. In the alternative seismic design procedures additional potentially plastic zones, with reduced beam cross‐sections (resembling the „dog‐bone“ detail), were provided near all girder ends, in order to ensure a larger strength of the columns compared to the one of the frame girders, when subjected to strong seismic actions. Two six‐storey concentrically braced frames, each having two spans of 6.0m and a storey height of 3.5m, were designed in turn according to the provisions of the relevant European and Romanian seismic design codes and four alternative seismic design procedures. The behaviour during the dynamic nonlinear analyses of all configurations of the concentrically braced frames, which resulted from the considered design procedures, was compared.

Authors

Institutions

Publication Details

Journal
ce/papers
Published
2025-12-01
DOI
https://doi.org/10.1002/cepa.70223
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Alternative Seismic Design for Six Storey Concentrically Braced Frames

Ramona Marcu, M M Stoian, Helmuth Köber, Ioana Claudia Tomescu
ce/papers
Seismic Performance and Analysis
article

Alternative Seismic Design for Six Storey Concentrically Braced Frames

Ramona Marcu, M M Stoian, Helmuth Köber, Ioana Claudia Tomescu
article en

Abstract

Abstract The present paper intends to illustrate the main advantages and disadvantages of four alternative seismic deign procedures for concentrically braced frames. In the alternative seismic design procedures additional potentially plastic zones, with reduced beam cross‐sections (resembling the „dog‐bone“ detail), were provided near all girder ends, in order to ensure a larger strength of the columns compared to the one of the frame girders, when subjected to strong seismic actions. Two six‐storey concentrically braced frames, each having two spans of 6.0m and a storey height of 3.5m, were designed in turn according to the provisions of the relevant European and Romanian seismic design codes and four alternative seismic design procedures. The behaviour during the dynamic nonlinear analyses of all configurations of the concentrically braced frames, which resulted from the considered design procedures, was compared.

ce/papersVol. 8(6)
Technical University of Civil Engineering of Bucharest (RO)
Sustainable cities and communities
Openalex Percentile: Top 33%
Seismic Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.