Direct method for Ra-226 analysis in water samples using ICP-QQQ-MS

The paper describes a method of determination of Ra-226 in natural water using ICP-QQQ-MS, Agilent 8900, that enables an efficient direct determination of Ra-226 with high sensitivity without using any reaction gas and separation procedures for interference removal. The matrix effect, together with the instability of the sensitivity are controlled by spiking the sample with Ra-226. The method is simple and fast with a detection limit around of 0.1 fg g<sup>-1</sup> (3.6 mBq kg<sup>-1</sup>), which is tenfold lower than required by the EU Directive for water consumption (40 mBq kg<sup>-1</sup>) and five times better than results obtained from alternative direct method for routine analysis described in the literature. The method can easily be implemented for routine analysis Ra-226 which was demonstrated by direct determination of Ra-226 in IAEA proficiency test water sample. This is the first time that the accuracy (trueness and precision) of a mass spectrometry method for the direct determination of Ra-226 has been tested and confirmed in an independent proficiency test.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-01-22
DOI
https://doi.org/10.1038/s41598-025-18775-4
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Direct method for Ra-226 analysis in water samples using ICP-QQQ-MS

Marko Štrok, Ivana Coha, Norbert Kávási
Scientific Reports
Analytical chemistry methods development
article

Direct method for Ra-226 analysis in water samples using ICP-QQQ-MS

Marko Štrok, Ivana Coha, Norbert Kávási
article en

Abstract

The paper describes a method of determination of Ra-226 in natural water using ICP-QQQ-MS, Agilent 8900, that enables an efficient direct determination of Ra-226 with high sensitivity without using any reaction gas and separation procedures for interference removal. The matrix effect, together with the instability of the sensitivity are controlled by spiking the sample with Ra-226. The method is simple and fast with a detection limit around of 0.1 fg g<sup>-1</sup> (3.6 mBq kg<sup>-1</sup>), which is tenfold lower than required by the EU Directive for water consumption (40 mBq kg<sup>-1</sup>) and five times better than results obtained from alternative direct method for routine analysis described in the literature. The method can easily be implemented for routine analysis Ra-226 which was demonstrated by direct determination of Ra-226 in IAEA proficiency test water sample. This is the first time that the accuracy (trueness and precision) of a mass spectrometry method for the direct determination of Ra-226 has been tested and confirmed in an independent proficiency test.

Scientific ReportsVol. 16(1)
Semmelweis University (HU), Jožef Stefan Institute (SI), Ruđer Bošković Institute (HR), Fukushima Prefectural Culture Center (JP)
Institut "Jožef Stefan", Semmelweis Egyetem, Institut Ruđer Bošković
Clean water and sanitation
Openalex Percentile: Top 79%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.