Low‐Cycle Fatigue Behaviour of Bolted Shear Connectors in Sustainable Composite Structures

Abstract Sustainable steel‐concrete composite structures are becoming more popular and widespread in construction due to their satisfactory load‐carrying capacity, environmental benefits, and their ability to be demounted in case of any damage or at the end of their lifespan. This can be achieved by adopting demountable shear connectors. Moreover, using one‐sided assembly types of bolted shear connectors paves the way for easing the installation process, thus reducing energy consumption and project costs as well as traffic congestion in case of bridge maintenance. However, the behaviour of one‐sided assembly bolted shear connectors in the fatigue regime, especially under the low‐cycle fatigue domain has not been studied. In the current study, the low‐cycle fatigue behaviour of the one‐sided assembly type of bolted shear connectors was investigated through conducting experiments utilising the direct shear method and the results were compared with those of welded‐headed studs. Experimental outcomes show that the low‐cycle fatigue behaviour of bolted shear connectors is a significant factor in the design of shear connectors in sustainable steel‐concrete composite structures. Additionally, results exhibited higher low‐cycle fatigue strength in comparison with headed studs. However, it was found that materials with higher ultimate strength tend to be more susceptible to low‐cycle fatigue loading.

Authors

Institutions

Publication Details

Journal
ce/papers
Published
2025-12-01
DOI
https://doi.org/10.1002/cepa.70094
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Low‐Cycle Fatigue Behaviour of Bolted Shear Connectors in Sustainable Composite Structures

Alireza Mohammadi Niaei, Fidelis Mashiri, Maryam Sadat Hosseini, Olivia Mirza
ce/papers
Structural Load-Bearing Analysis
article

Low‐Cycle Fatigue Behaviour of Bolted Shear Connectors in Sustainable Composite Structures

Alireza Mohammadi Niaei, Fidelis Mashiri, Maryam Sadat Hosseini, Olivia Mirza
article en

Abstract

Abstract Sustainable steel‐concrete composite structures are becoming more popular and widespread in construction due to their satisfactory load‐carrying capacity, environmental benefits, and their ability to be demounted in case of any damage or at the end of their lifespan. This can be achieved by adopting demountable shear connectors. Moreover, using one‐sided assembly types of bolted shear connectors paves the way for easing the installation process, thus reducing energy consumption and project costs as well as traffic congestion in case of bridge maintenance. However, the behaviour of one‐sided assembly bolted shear connectors in the fatigue regime, especially under the low‐cycle fatigue domain has not been studied. In the current study, the low‐cycle fatigue behaviour of the one‐sided assembly type of bolted shear connectors was investigated through conducting experiments utilising the direct shear method and the results were compared with those of welded‐headed studs. Experimental outcomes show that the low‐cycle fatigue behaviour of bolted shear connectors is a significant factor in the design of shear connectors in sustainable steel‐concrete composite structures. Additionally, results exhibited higher low‐cycle fatigue strength in comparison with headed studs. However, it was found that materials with higher ultimate strength tend to be more susceptible to low‐cycle fatigue loading.

ce/papersVol. 8(6)
Western Sydney University (AU)
Affordable and clean energy
Openalex Percentile: Top 33%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.