Security domain modeling and suppression of commutation failure for LCC-HVDC considering AC-DC coupling
• Under the limitations of DC current and firing advance angle, the feasible ranges of active and exchanged reactive power of inverter station are established by deriving the expressions of them. • By deriving the expression of AC bus voltage at inverter station while adhering to flow constraint, the feasible range of AC bus voltage and power is established, taking into account the AC-DC coupling. • Under the constraints of DC current and firing advance angle, the feasible ranges of AC bus voltage and power are characterized to establish the security domain of inverter station, taking into account the AC-DC coupling. • The control methods of DC current and firing advance angle are proposed to suppress the SCF with the consideration of power transmission through creating a calculation method of DC current and firing advance angle to maximize the active power with the constraint of extinction angle. In line-commuted converter based high voltage direct current (LCC-HVDC), commutation failure (CF) is a main source of danger. The CF is usually suppressed by regulating the single electrical quantity. However, for the active and reactive power of inverter station, the combination of DC current and voltage, AC bus voltage, firing angle (FA) and extinction angle (EA) is the determining influence. The regulation of any electrical quantity leads to variations in power, thereby influencing the AC bus voltage and subsequently inducing variations in the DC current, DC voltage, and EA. The neglect of AC-DC coupling affects the suppression of CF and limits power transmission. The formulation of the active and reactive power of inverter station has been deduced. Considering the constraints imposed by DC current and firing advance angle (FAA), the power feasible range is established. The feasible range of AC bus voltage and power is built considering AC-DC coupling. The commutation security domain of inverter station to avoid CF is modeled. To maximize the active power, formulations of DC current and FAA are proposed. Taking into account the power transmission, an improved suppression method of subsequent CF is proposed. The CIGRE standardized model is utilized to verify the method.
Authors
- Mingyu Pang
- Taiyu Xiao
- Shoudong Xu
- Jinxin Ouyang
- Chao Xiao
Institutions
- Chongqing University (CN)
Publication Details
- Journal
- Energy Conversion and Management X
- Published
- 2026-01-22
- DOI
- https://doi.org/10.1016/j.ecmx.2026.101608
- Primary Topic
- HVDC Systems and Fault Protection
- Type
- article
- Field-Weighted Citation Impact
- 0.00