Security domain modeling and suppression of commutation failure for LCC-HVDC considering AC-DC coupling

• Under the limitations of DC current and firing advance angle, the feasible ranges of active and exchanged reactive power of inverter station are established by deriving the expressions of them. • By deriving the expression of AC bus voltage at inverter station while adhering to flow constraint, the feasible range of AC bus voltage and power is established, taking into account the AC-DC coupling. • Under the constraints of DC current and firing advance angle, the feasible ranges of AC bus voltage and power are characterized to establish the security domain of inverter station, taking into account the AC-DC coupling. • The control methods of DC current and firing advance angle are proposed to suppress the SCF with the consideration of power transmission through creating a calculation method of DC current and firing advance angle to maximize the active power with the constraint of extinction angle. In line-commuted converter based high voltage direct current (LCC-HVDC), commutation failure (CF) is a main source of danger. The CF is usually suppressed by regulating the single electrical quantity. However, for the active and reactive power of inverter station, the combination of DC current and voltage, AC bus voltage, firing angle (FA) and extinction angle (EA) is the determining influence. The regulation of any electrical quantity leads to variations in power, thereby influencing the AC bus voltage and subsequently inducing variations in the DC current, DC voltage, and EA. The neglect of AC-DC coupling affects the suppression of CF and limits power transmission. The formulation of the active and reactive power of inverter station has been deduced. Considering the constraints imposed by DC current and firing advance angle (FAA), the power feasible range is established. The feasible range of AC bus voltage and power is built considering AC-DC coupling. The commutation security domain of inverter station to avoid CF is modeled. To maximize the active power, formulations of DC current and FAA are proposed. Taking into account the power transmission, an improved suppression method of subsequent CF is proposed. The CIGRE standardized model is utilized to verify the method.

Authors

Institutions

Publication Details

Journal
Energy Conversion and Management X
Published
2026-01-22
DOI
https://doi.org/10.1016/j.ecmx.2026.101608
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Security domain modeling and suppression of commutation failure for LCC-HVDC considering AC-DC coupling

Mingyu Pang, Taiyu Xiao, Shoudong Xu, Jinxin Ouyang et al.
Energy Conversion and Management X
HVDC Systems and Fault Protection
article

Security domain modeling and suppression of commutation failure for LCC-HVDC considering AC-DC coupling

Mingyu Pang, Taiyu Xiao, Shoudong Xu, Jinxin Ouyang, Chao Xiao
article en

Abstract

• Under the limitations of DC current and firing advance angle, the feasible ranges of active and exchanged reactive power of inverter station are established by deriving the expressions of them. • By deriving the expression of AC bus voltage at inverter station while adhering to flow constraint, the feasible range of AC bus voltage and power is established, taking into account the AC-DC coupling. • Under the constraints of DC current and firing advance angle, the feasible ranges of AC bus voltage and power are characterized to establish the security domain of inverter station, taking into account the AC-DC coupling. • The control methods of DC current and firing advance angle are proposed to suppress the SCF with the consideration of power transmission through creating a calculation method of DC current and firing advance angle to maximize the active power with the constraint of extinction angle. In line-commuted converter based high voltage direct current (LCC-HVDC), commutation failure (CF) is a main source of danger. The CF is usually suppressed by regulating the single electrical quantity. However, for the active and reactive power of inverter station, the combination of DC current and voltage, AC bus voltage, firing angle (FA) and extinction angle (EA) is the determining influence. The regulation of any electrical quantity leads to variations in power, thereby influencing the AC bus voltage and subsequently inducing variations in the DC current, DC voltage, and EA. The neglect of AC-DC coupling affects the suppression of CF and limits power transmission. The formulation of the active and reactive power of inverter station has been deduced. Considering the constraints imposed by DC current and firing advance angle (FAA), the power feasible range is established. The feasible range of AC bus voltage and power is built considering AC-DC coupling. The commutation security domain of inverter station to avoid CF is modeled. To maximize the active power, formulations of DC current and FAA are proposed. Taking into account the power transmission, an improved suppression method of subsequent CF is proposed. The CIGRE standardized model is utilized to verify the method.

Energy Conversion and Management XVol. 30
Chongqing University (CN)
Affordable and clean energy
Openalex Percentile: Top 79%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.