Simultaneous high-resolution electrophysiology measurements and motion tracking of ex vivo rat uterine smooth muscle activity

Uterine smooth muscle undergoes electrical, chemical, and mechanical transients during phasic contraction. The spread of electrical activity precedes the mechanical contraction of muscle fibers, and the initiation and coordination of these events is critical to uterine function, in both pregnancy and non-pregnancy. Characterization of non-pregnant activity is scarce, and understanding of the relationship between electrical and mechanical events is not well understood. Isolated uterine horns from virgin female Wistar rats were used in this study. Electrical and mechanical activity were assessed ex vivo using high-resolution surface electrodes and motion tracking. Electrophysiology data were analyzed to provide frequency and timing metrics; displacement and velocity were quantified from the motion-tracking data. Major coordinated electrical events were correlated with longitudinal displacement of tissue markers, with the peak displacement occurring at or near the point of electrical signal initiation. Overall, 82% of electrical slow wave events were associated with mechanical displacement of tracking points. Minor uncoordinated electrical events were accompanied by little or no displacement, indicating that a level or coordination is required to achieve tissue-level contraction. Electrical slow wave propagation occurred at a higher speed (0.60 ± 0.04 mm/s) than mechanical tissue displacement velocity (0.42 ± 0.39 mm/s, p = 0.0024), and electrical propagation speed was lowest during metestrus when compared with estrus (p = 0.0042) and diestrus (p = 0.0066). This technique advances our understanding of the electro-mechanical properties of the non-pregnant rat uterus and provides an avenue to measure electrical-mechanical coupling in ex vivo uterine tissue preparations.

Authors

Institutions

Publication Details

Journal
Reproduction
Published
2026-01-05
DOI
https://doi.org/10.1093/reprod/xaaf029
Primary Topic
Preterm Birth and Chorioamnionitis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simultaneous high-resolution electrophysiology measurements and motion tracking of ex vivo rat uterine smooth muscle activity

Alys R. Clark, Jarrah M. Dowrick, Leo K. Cheng, Mathias W. Roesler et al.
Reproduction
Preterm Birth and Chorioamnionitis
article

Simultaneous high-resolution electrophysiology measurements and motion tracking of ex vivo rat uterine smooth muscle activity

Alys R. Clark, Jarrah M. Dowrick, Leo K. Cheng, Mathias W. Roesler, Amy S. Garrett
article en

Abstract

Uterine smooth muscle undergoes electrical, chemical, and mechanical transients during phasic contraction. The spread of electrical activity precedes the mechanical contraction of muscle fibers, and the initiation and coordination of these events is critical to uterine function, in both pregnancy and non-pregnancy. Characterization of non-pregnant activity is scarce, and understanding of the relationship between electrical and mechanical events is not well understood. Isolated uterine horns from virgin female Wistar rats were used in this study. Electrical and mechanical activity were assessed ex vivo using high-resolution surface electrodes and motion tracking. Electrophysiology data were analyzed to provide frequency and timing metrics; displacement and velocity were quantified from the motion-tracking data. Major coordinated electrical events were correlated with longitudinal displacement of tissue markers, with the peak displacement occurring at or near the point of electrical signal initiation. Overall, 82% of electrical slow wave events were associated with mechanical displacement of tracking points. Minor uncoordinated electrical events were accompanied by little or no displacement, indicating that a level or coordination is required to achieve tissue-level contraction. Electrical slow wave propagation occurred at a higher speed (0.60 ± 0.04 mm/s) than mechanical tissue displacement velocity (0.42 ± 0.39 mm/s, p = 0.0024), and electrical propagation speed was lowest during metestrus when compared with estrus (p = 0.0042) and diestrus (p = 0.0066). This technique advances our understanding of the electro-mechanical properties of the non-pregnant rat uterus and provides an avenue to measure electrical-mechanical coupling in ex vivo uterine tissue preparations.

ReproductionVol. 171(2)
Auckland Institute of Studies (NZ), University of Auckland (NZ), Auckland University of Technology (NZ)
Good health and well-being
Openalex Percentile: Top 80%
Preterm Birth and Chorioamnionitis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.