Knee joint distraction in tibiofemoral osteoarthritis: evaluating the impact of bone pins and springs on the mechanical performance of the KneeReviver device

Knee joint distraction is a joint-preserving treatment for younger patients (45-65 years) with tibiofemoral osteoarthritis, aiming to unload cartilage by temporarily separating the femur and tibia. The KneeReviver (KR) is a distraction device specifically developed for this purpose. Despite clinical successes, inter-patient variability in outcomes indicate a limited understanding of its mechanical behavior. This study evaluates the mechanical contribution of KR's bone pins and springs using finite element (FE) modeling. Variations in bone pin length, diameter, and the inclusion of KR's springs were assessed in terms of contact mechanics, initial joint gap creation, and gap narrowing under axial load. Results showed that smaller pin diameters, longer pin lengths, and the inclusion of springs increased cartilage contact pressures, reduced initial joint gaps, and led to earlier joint gap closure. These findings identify critical mechanical factors that may inform future device design, patient-specific configurations, and surgical application strategies.

Authors

Institutions

Publication Details

Journal
Medical Engineering & Physics
Published
2026-01-23
DOI
https://doi.org/10.1088/1873-4030/ae2918
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Knee joint distraction in tibiofemoral osteoarthritis: evaluating the impact of bone pins and springs on the mechanical performance of the KneeReviver device

D. P. B. Janssen, F Janssen, Thom Bitter, Nico Verdonschot
Medical Engineering & Physics
Total Knee Arthroplasty Outcomes
article

Knee joint distraction in tibiofemoral osteoarthritis: evaluating the impact of bone pins and springs on the mechanical performance of the KneeReviver device

D. P. B. Janssen, F Janssen, Thom Bitter, Nico Verdonschot
article en

Abstract

Knee joint distraction is a joint-preserving treatment for younger patients (45-65 years) with tibiofemoral osteoarthritis, aiming to unload cartilage by temporarily separating the femur and tibia. The KneeReviver (KR) is a distraction device specifically developed for this purpose. Despite clinical successes, inter-patient variability in outcomes indicate a limited understanding of its mechanical behavior. This study evaluates the mechanical contribution of KR's bone pins and springs using finite element (FE) modeling. Variations in bone pin length, diameter, and the inclusion of KR's springs were assessed in terms of contact mechanics, initial joint gap creation, and gap narrowing under axial load. Results showed that smaller pin diameters, longer pin lengths, and the inclusion of springs increased cartilage contact pressures, reduced initial joint gaps, and led to earlier joint gap closure. These findings identify critical mechanical factors that may inform future device design, patient-specific configurations, and surgical application strategies.

Medical Engineering & PhysicsVol. 147(2)
Radboud University Nijmegen (NL), Radboud University Medical Center (NL), Radboud Institute for Molecular Life Sciences (NL), University of Twente (NL)
Nederlandse Organisatie voor Wetenschappelijk Onderzoek
Openalex Percentile: Top 80%
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.