Adaptive reclosing scheme for flexible HVDC grid with single-pole ground fault based on residual voltage zero-crossing detection

To avoid the issue of blind reclosing in conventional flexible high voltage direct current (HVDC) grid, investigating an adaptive reclosing scheme capable of identifying fault nature and duration is essential. This paper proposes a single-pole ground fault adaptive reclosing scheme based on residual voltage zero-crossing detection for flexible HVDC grid equipped with hybrid DC circuit breakers (HDCCB). First, the working principle of HDCCB and the expressions of residual voltage under different fault natures are analysed. Secondly, based on the zero-crossing detection principle, the differences in zero-crossing characteristics before and after the fault are used to identify the fault nature and calculate the fault duration. Finally, a flexible HVDC grid model is developed using the real-time digital simulator (RTDS) platform to verify the proposed scheme through simulation. The results demonstrate that the adaptive reclosing scheme accurately identifies fault nature and calculates fault duration with an error margin of less than 3 ms, exhibiting significant tolerance to fault resistance.

Authors

Publication Details

Journal
International Journal of Electrical Power & Energy Systems
Published
2026-01-23
DOI
https://doi.org/10.1016/j.ijepes.2025.111519
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Adaptive reclosing scheme for flexible HVDC grid with single-pole ground fault based on residual voltage zero-crossing detection

Yutao Tang, Feng Gong, Yue Dai, Hongchun Shu
International Journal of Electrical Power & Energy Systems
HVDC Systems and Fault Protection
article

Adaptive reclosing scheme for flexible HVDC grid with single-pole ground fault based on residual voltage zero-crossing detection

Yutao Tang, Feng Gong, Yue Dai, Hongchun Shu
article en

Abstract

To avoid the issue of blind reclosing in conventional flexible high voltage direct current (HVDC) grid, investigating an adaptive reclosing scheme capable of identifying fault nature and duration is essential. This paper proposes a single-pole ground fault adaptive reclosing scheme based on residual voltage zero-crossing detection for flexible HVDC grid equipped with hybrid DC circuit breakers (HDCCB). First, the working principle of HDCCB and the expressions of residual voltage under different fault natures are analysed. Secondly, based on the zero-crossing detection principle, the differences in zero-crossing characteristics before and after the fault are used to identify the fault nature and calculate the fault duration. Finally, a flexible HVDC grid model is developed using the real-time digital simulator (RTDS) platform to verify the proposed scheme through simulation. The results demonstrate that the adaptive reclosing scheme accurately identifies fault nature and calculates fault duration with an error margin of less than 3 ms, exhibiting significant tolerance to fault resistance.

International Journal of Electrical Power & Energy SystemsVol. 175
Openalex Percentile: Top 80%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Adaptive reclosing scheme for flexible HVDC grid with single-pole ground fault based on residual voltage zero-crossing detection — Yutao Tang, Feng Gong, et al. · International Journal of Electrical Power & Energy Systems (2026) | TGRS Research Map | TGRS